![GSi 21' Diameter Gamma Assembly Instructions Manual Download Page 34](http://html1.mh-extra.com/html/gsi/21-diameter-gamma/21-diameter-gamma_assembly-instructions-manual_2274962034.webp)
4. Roof Assembly
34
PNEG-2145
21' Diameter Gamma Roof Assembly Instructions
Roof Ring Location (Optional)
To determine the location of the roof rings, start at the wide or eave of the roof panel and count up
each hole. Having counted up the required distance, as described in the table below, install the
appropriate brackets.
NOTE:
The
last roof ring pipe may need to be cut to length.
Figure 4U Roof Ring Location
Ref #
Description
A
Roof Step
B
Roof Panel
C
Roof Ring
Roof Ring Part
Number
Bin Diameter Roof
Ring Location
Roof Ring Location
From Eave End
Roof Ring Color Code
Number of
Pipes per Ring
CRP-4703
21
3
rd
Hole
Red/White
5
NOTE: Image is graphical representation only. Use the table to determine the roof ring location for your bin.