7. 4.00" Corrugation Farm Commercial Hopper Tanks (FCHT) 4-6 Rings
80
PNEG-1451
Ladder, Safety Cage and Platform for Hopper Tanks
Eave Platform Mounting Angle Installation
shows the location of the platform mounting angles (B). Each angle must be mounted starting
8" above the top horizontal seam of the second ring with the first mounting angle (B) offset 9-3/8" from the
right hand starter bracket (A). The second mounting angle (B) must be located 56-1/4" from the first
mounting angle (B). The dimensions and locations of these angles are critical for proper fit of all parts.
Using the platform mounting angels (B) as guides, field drill 3/8" holes in the sidewall every 8".
Figure 7H
Ref #
Part #
Description
A
LDR-4347
R.H. Starter Bracket
B
TDP-5008N
Fluorescent Green/Black Platform Mounting Angles (Field drill 3/8" holes on 8" centers.)
C
Roof Ladder
D
Manway Panel
E
18-3/4" Reference
F
44" Typical
Summary of Contents for PNEG-1451
Page 2: ...2 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks...
Page 18: ...18 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks NOTES...
Page 40: ...40 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks NOTES...
Page 70: ...70 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks NOTES...