8. 4.00" Corrugation Farm Commercial Hopper Tank (FCHT) 7-9 Rings
PNEG-1451
Ladder, Safety Cage and Platform for Hopper Tanks
107
Access Door/Base Platform Mounting Angle Installation
shows the location of the access door platform mounting angles. All four (4) angles must be
mounted starting 16" above the top horizontal seam of the bottom ring (E) with the first mounting angle
directly in line with the left hand eave mounting angle. The second mounting angle must be located
56-1/4" to the left of the first mounting angle. The remaining two (2) mounting angles will be installed in
the stiffeners located on each side of the access door. When installed correctly, there should be 37-1/2"
between the two (2) sets of mounting angles. Pay careful attention when installing these angles. The
dimensions and locations of these angles are very critical to assure proper fit of all parts.
Figure 8R
Ref #
Description
A
Eave platform mounting angles shown for reference only.
for proper installation.
B
Access Door Panel (Must be centered between mounting angles.)
C
Access Door Platform mounting Angles (TDP-5008N)
D
The right hand platform mounting angle must be in line with the left hand eave platform mounting angle.
E
Bottom Ring
F
Base Platform Mounting Angles (TDP-5008N) (Field drill 3/8" holes on 8" centers.)
G
37-1/2" Reference
H
4" Typical
I
for distance between mounting angles.
Summary of Contents for PNEG-1451
Page 2: ...2 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks...
Page 18: ...18 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks NOTES...
Page 40: ...40 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks NOTES...
Page 70: ...70 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks NOTES...
Page 92: ...92 PNEG 1451 Ladder Safety Cage and Platform for Hopper Tanks NOTES...