Hexylon High-performance portable meter
40
carrier with the minimum MER, and will be moving
searching the carrier with minimum MER each
time.
6.4.8.2.- Options context menu
• Quality profile: allows to select the quality profile
• Powering:
-
VDC: Selects the preamplifier powering.
• Carrier: Allows to select the carrier where the user
wants to measure the MER.
• Restart Att: restarts the control attenuation.
• Quality profile: allows to select the quality profile
• Powering:
-
VDC: Selects the preamplifier powering.
• Min. Carrier: Allows you to select the minimum
carrier to be shown in the graph.
• Max. Carrier: Allows you to select the maximum
carrier to be shown in the graph.
• Reset Positions: Sets the minimum and maximum
carriers shown in the graph to the maximum and
minimum carriers of the channel.
6.4.9.- Uncorrected packets (RF Input)
This feature makes an uncorrected packet analysis
during a timer interval selected by the user.
6.4.9.1.- Main window
• ESR (Errored Second Ratio): Number of erroneous
seconds within an observation window of the past
20 seconds).
• Total analysis: Start and end time of the analysis,
and number of uncorrected packets in all the
intervals analysed.
• Current interval: Start and end time of the current
interval, and number of uncorrected packets.
• Previous interval: Start and end time of the
previous interval and number of uncorrected
packets.
• Worst interval: Start and end time of the interval
with more uncorrected packets, and number
of uncorrected packets in the worst interval of
analysis since it was started.
• Locked: Time gone by since the demodulator
locked to the digital signal the last time, longest
time the digital signal was locked, and number of
lockings.
• Unlocked: Time gone by since the demodulator
unlocked to the digital signal the last time, longest
time the digital signal was unlocked, and number
of unlockings.
• Error-free: Time gone by since last uncorrected
packet, and longest time gone by since last
uncorrected packet.
Data about unlockings
Data of the uncorrected
packets analysis
Summary of Contents for 901622
Page 2: ......
Page 76: ...Hexylon High performance portable meter 76...
Page 77: ......
Page 78: ...901622_1 38_EN...