10
NOTE:
When changing to and from speed 1, the
cover of the speed switch module must be removed
and fitted on the other side of the switch.
4. Fit the terminal box cover back onto the terminal
box and tighten the four screws in the cover.
5. Switch on the electrical supply.
Check that the green indicator light is perma-
nently on or flashing.
NOTE:
The speed switch module must never be
used as an on/off switch.
4.3.2 Two-speed pumps, 3 x 460 V and 575 V
The speed setting in the terminal box can be
changed to two positions. The speed in the two posi-
tions appears in the table below (also see fig. 13 on
page 9).
Change the pump performance as follows:
The speed is changed by the position of the jumpers
in the terminals. The jumpers are fitted according to:
• figure 15 for speed 1 - low speed
• figure 16 for speed 2 - high speed.
Fig. 15
Speed 1 (low speed)
Fig. 16
Speed 2 (high speed)
Fig. 17
Terminal box
Speed step
Speed in % of maximum speed
1
approx. 75%
2
100%
WARNING!
Never make any connections in the pump
terminal box unless the electrical supply
has been switched off.
T
M
03
77
34
48
06
TM
0
3
7
733
4
806
L3
L1
L2
P1
P2
T5
T4
T6
T3
T2
T1
Jumper wire
L3
L1
L2
P1
P2
T5
T4
T6
T3
T2
T1
Jumper wire
TM
03
77
39
48
06
L1
L2
L3
P1
P2
T6
T4
T5
T1
T2
T3
Summary of Contents for VersaFlo UPS
Page 1: ...VersaFlo UPS GRUNDFOS INSTRUCTIONS Installation and operating instructions ...
Page 15: ...15 Internal wiring UPS Terminal plug in stator Three phase 460 575 V 1 7 3 9 5 11 13 15 ...
Page 32: ...32 Câblage interne UPS Fiche de raccordement du stator Triphasé 460 575 V 1 7 3 9 5 11 13 15 ...
Page 37: ...37 ...
Page 38: ...38 ...