6.3 Replacing the terminal box or capacitor
Fig. 22
Terminal box
If the terminal box is replaced, make certain the elec-
trical information listed on the new box matches the
information listed on the old box, and that it is com-
patible with the pump and incoming electrical supply.
For all terminal boxes, it is very important to tightly
secure the frame grounding screw through the termi-
nal box, so that a proper connection between the ter-
minal box and motor is made.
7. Disposal
This product or parts of it must be disposed of in
an environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
TM
03 774
2 480
6
Frame ground
screw hole
Standard
module
Speed
switch
Electrical information
All
1.
Before replacing the terminal box or capacitor, make sure the power is OFF.
2.
Remove the terminal box cover by completely loosening all four torx/standard
screws.
3.
Remove the speed switch (noting its position) by pulling firmly and evenly on both
sides of it. (Not for 460/575 V).
Capacitor
a.4.
Capacitor replacement, single-phase pumps only:
Disconnect the two connec-
tor clips from the capacitor and unscrew the complete plastic strain relief nut.
Remove capacitor wire and strain relief.
a.5.
Screw in new complete strain relief nut and connect new clip connectors. Pull
excess sheathed cable out of terminal box, being sure to leave at least 1/8" of
sheath inside of terminal box.
Terminal box
b.4.
Terminal box replacement:
Disconnect all wiring, remove the three phillips-head
screws holding the terminal box in place and remove the terminal box by pulling
firmly and evenly on both sides.
b.5.
Check that the clear rubber gasket is in place around the terminal box connector
stem, carefully press the terminal box into the stator socket, replace the three
phillips-head terminal box screws and replace wiring.
All
6.
Replace the speed switch to its proper position, making sure to push it all the way
in. (Not for 460/575 V).
7.
Replace the terminal box cover and tighten all four torx/standard screws.
8.
Switch on electrical power supply. The pump is now ready for operation.
Subject to alterations.
Summary of Contents for VersaFlo UPS
Page 1: ...VersaFlo UPS GRUNDFOS INSTRUCTIONS Installation and operating instructions ...
Page 15: ...15 Internal wiring UPS Terminal plug in stator Three phase 460 575 V 1 7 3 9 5 11 13 15 ...
Page 32: ...32 Câblage interne UPS Fiche de raccordement du stator Triphasé 460 575 V 1 7 3 9 5 11 13 15 ...
Page 37: ...37 ...
Page 38: ...38 ...