English (GB)
55
19. Grundfos Eye
The operating condition of the pump is indicated by Grundfos Eye
on the control panel. See fig.
, A.
Fig. 78
Grundfos Eye
TM
0
5
5
993
4
3
12
A
Grundfos Eye
Indication
Description
No lights are on.
The power is off.
The pump is not running.
The two opposite green indicator lights are
rotating in the direction of rotation of the
pump when seen from the non-drive end.
The power is on.
The pump is running.
The two opposite green indicator lights are
permanently on.
The power is on.
The pump is not running.
One yellow indicator light is rotating in the
direction of rotation of the pump when seen
from the non-drive end.
Warning.
The pump is running.
One yellow indicator light is permanently on.
Warning.
The pump has stopped.
The two opposite red indicator lights are
flashing simultaneously.
Alarm.
The pump has stopped.
The green indicator light in the middle
flashes quickly four times.
This is a feedback signal which the pump gives in
order to ensure identification of itself.
The green indicator light in the middle
flashes continuously.
Grundfos GO or another pump is trying to
communicate with the pump. Press
on the
pump control panel to allow communication.
The green indicator light in the middle is
permanently on.
Remote control with Grundfos GO via radio.
The pump is communicating with Grundfos GO
via radio connection.
The green indicator light in the middle
flashes quickly while Grundfos GO is
exchanging data with the pump. It will take a
few seconds.
Remote control with Grundfos GO via infrared
light.
The pump is receiving data from Grundfos GO via
infrared communication.