6.4 Fitting the cable plug to the motor 

The cable plug supplied with the motor is factory-
greased. Check that the plug is greased correctly. 

To fit the cable plug, proceed as follows:

1. Check that the cable is of the correct type, cross-

section and length.

2. Check that the mains on the location has correct 

connection to earth.

3. Check that the motor socket is clean and dry.

Make sure that the loose gasket has been fitted.

4. Press the cable plug onto the motor socket. 

The plug cannot be fitted wrongly. See fig. 8.

Fig. 8

5. Fit and tighten the four screws (1 - 1.5 Nm). 

See fig. 8

When the plug has been fitted, there must not be a 
clearance between the motor and the cable plug.

6.5 Fitting the cable guard

To fit the cable guard, proceed as follows:

1. Make sure that the submersible drop cable lies 

flat in the cable guard.

2. Place the cable guard in the groove in the cable 

plug. The two flaps of the cable guard must 
engage with the upper edge of the pump sleeve. 
See fig. 9.

Fig. 9

3. Fasten the cable guard to the pump suction 

strainer with the two self-tapping screws 
supplied. See fig. 10.

Fig. 10

Warning

The motor plug must under no 
circumstances be removed by the user.

The following description is exclusively 
intended for service personnel. 

If the motor cable is to be replaced, see 
section 5.1 General.

The cable with plug must be fitted or 
removed by an authorised Grundfos 
service workshop or a similarly qualified 
person. 

T

M

02

 96

05

 35

0

4

TM

0

2

 9

613

 3

504

T

M

01

 44

27

 02

99

Summary of Contents for SQE-NE Series

Page 1: ...on 12 6 1 General 12 6 2 Assembly of pump part and motor 12 6 3 Removal of non return valve 12 6 4 Fitting the cable plug to the motor 13 6 5 Fitting the cable guard 13 6 6 Cable sizing 14 6 7 Fitting...

Page 2: ...ator As a minimum the generator output must be equal to the motor P1 kW 10 Starting current The motor starting current is equal to the highest value stated on the motor nameplate Power factor PF 1 Mot...

Page 3: ...ng a screwdriver or a similar tool 4 Inject motor liquid into the motor with a filling syringe or the like 5 To allow possible air to escape move the motor from side to side 6 Refit the filling plug a...

Page 4: ...arked with the following symbol Supply voltage 1 x 200 240 V 10 6 50 60 Hz PE The current consumption can only be measured by means of a true RMS instrument If other instruments are used the value mea...

Page 5: ...be used on the clamping faces of the pump part See fig 6 Fig 6 When pump part and motor have been assembled correctly there must not be a clearance between pump part and motor 6 3 Removal of non retur...

Page 6: ...earance between the motor and the cable plug 6 5 Fitting the cable guard To fit the cable guard proceed as follows 1 Make sure that the submersible drop cable lies flat in the cable guard 2 Place the...

Page 7: ...Fitting the submersible drop cable It is recommended to join the submersible drop cable and the motor cable by means of a Grundfos cable termination kit type KM For larger cross sections please contac...

Page 8: ...lation depths Maximum installation depth below the static water level 150 metres See fig 11 Minimum installation depths below the dynamic water level Vertical installation During start up and operatio...

Page 9: ...switch and diaphragm tank during starting will be lower than the pump cut in pressure set on the pressure switch pcut in This lower pressure is called minimum pressure pmin pmin is equal to the desir...

Page 10: ...ce tools are available from Grundfos The Grundfos Service Manual is available on request The pumps can be serviced at a Grundfos service centre 9 1 Contaminated pumps If Grundfos is requested to servi...

Page 11: ...n the electric installation are blown Replace the blown fuses If the new ones blow too the electric installation and the submersible drop cable should be checked b The ELCB or the voltage operated ELC...

Page 12: ...e is defective Replace the riser pipe i Undervoltage has occurred Check the power supply 4 Frequent starts and stops a The differential of the pressure switch between the start and stop pressures is t...

Page 13: ...d neutral Connect the voltmeter to the terminals at the connection The voltage should when the motor is loaded be within the range specified in section 5 Electrical connection Large variations in supp...

Reviews: