background image

English (GB)

10

4. Preparation 

Grundfos MS 3 and MSE 3 submersible motors have 
water-lubricated slide bearings. No additional 
lubrication is required.

The submersible motors are factory-filled with a 
special Grundfos motor liquid (type SML 2), which is 
frost-proof down to - 20 °C and preserved to prevent 
the growth of bacteria. 
The level of motor liquid is decisive for the operating 
life of the bearings and consequently the life of the 
motor.

4.1 Refilling of motor liquid

If for any reason the motor liquid has been drained or 
lost, the motor must be refilled with Grundfos motor 
liquid SML 2.

To refill the motor, proceed as follows:

1. Remove the cable guard and separate the pump 

part from the motor.

Fig. 1

2. Place the motor in vertical position with an 

inclination of approx. 10 °.

3. Remove the filling plug using a screwdriver or 

a similar tool.

4. Inject motor liquid into the motor with a filling 

syringe or the like.

5. To allow possible air to escape, move the motor 

from side to side.

6. Refit the filling plug and make sure it is tight.

7. Assemble pump part and motor.

8. Refit the cable guard.

The pump is now ready for installation.

4.2 Positional requirements

The pump is suitable for vertical as well as horizontal 
installation, however, the pump shaft must never fall 
below the horizontal plane. See fig. 2. 

Fig. 2

If the pump is to be installed horizontally, e.g. in a 
tank, and there is a risk that the pump might be 
covered by mud, it must be fitted in a flow sleeve.

For installation depths, see section 6.8.2.

4.3 Liquid temperatures/cooling 

Figure 3 shows an SQ/SQE pump installed in a 
borehole. The pump is operating.

Figure 3 illustrates the following:

borehole diameter

pump diameter

temperature of pumped liquid

flow past the motor to the pump suction strainer.

TM

02

 96

06

 35

04

10

TM

01 137

5 439

7

Allowed

Not allowed

Summary of Contents for SQE-NE Series

Page 1: ...on 12 6 1 General 12 6 2 Assembly of pump part and motor 12 6 3 Removal of non return valve 12 6 4 Fitting the cable plug to the motor 13 6 5 Fitting the cable guard 13 6 6 Cable sizing 14 6 7 Fitting...

Page 2: ...ator As a minimum the generator output must be equal to the motor P1 kW 10 Starting current The motor starting current is equal to the highest value stated on the motor nameplate Power factor PF 1 Mot...

Page 3: ...ng a screwdriver or a similar tool 4 Inject motor liquid into the motor with a filling syringe or the like 5 To allow possible air to escape move the motor from side to side 6 Refit the filling plug a...

Page 4: ...arked with the following symbol Supply voltage 1 x 200 240 V 10 6 50 60 Hz PE The current consumption can only be measured by means of a true RMS instrument If other instruments are used the value mea...

Page 5: ...be used on the clamping faces of the pump part See fig 6 Fig 6 When pump part and motor have been assembled correctly there must not be a clearance between pump part and motor 6 3 Removal of non retur...

Page 6: ...earance between the motor and the cable plug 6 5 Fitting the cable guard To fit the cable guard proceed as follows 1 Make sure that the submersible drop cable lies flat in the cable guard 2 Place the...

Page 7: ...Fitting the submersible drop cable It is recommended to join the submersible drop cable and the motor cable by means of a Grundfos cable termination kit type KM For larger cross sections please contac...

Page 8: ...lation depths Maximum installation depth below the static water level 150 metres See fig 11 Minimum installation depths below the dynamic water level Vertical installation During start up and operatio...

Page 9: ...switch and diaphragm tank during starting will be lower than the pump cut in pressure set on the pressure switch pcut in This lower pressure is called minimum pressure pmin pmin is equal to the desir...

Page 10: ...ce tools are available from Grundfos The Grundfos Service Manual is available on request The pumps can be serviced at a Grundfos service centre 9 1 Contaminated pumps If Grundfos is requested to servi...

Page 11: ...n the electric installation are blown Replace the blown fuses If the new ones blow too the electric installation and the submersible drop cable should be checked b The ELCB or the voltage operated ELC...

Page 12: ...e is defective Replace the riser pipe i Undervoltage has occurred Check the power supply 4 Frequent starts and stops a The differential of the pressure switch between the start and stop pressures is t...

Page 13: ...d neutral Connect the voltmeter to the terminals at the connection The voltage should when the motor is loaded be within the range specified in section 5 Electrical connection Large variations in supp...

Reviews: