background image

English (GB)

20

11. Checking the power supply 

12. Environment

During handling, operation, storage and transport, 
all environment regulations dealing with the handling 
of hazardous materials must be observed.

In case of doubt, please contact Grundfos or the 
local authorities.

13. Disposal

This product or parts of it must be disposed of in an 
environmentally sound way:

1. Use the public or private waste collection service.

2. If this is not possible, contact the nearest 

Grundfos company or service workshop.

Warning

Before starting any work on the pump/motor, make sure that the power supply has been 
switched off and that it cannot be accidentally switched on. 

1. Supply voltage

T

M

00

 13

71

 49

04

Measure the voltage (RMS) 
between phase and neutral. 
Connect the voltmeter to the 
terminals at the connection.

The voltage should, when the motor is 
loaded, be within the range specified in 
section 5. Electrical connection.
Large variations in supply voltage indicate 
poor power supply, and the pump should be 
stopped until the defect has been remedied.

2. Current consumption

TM

00

 1

372

 50

82

Measure the current (RMS) 
while the pump is operating 
at a constant discharge head 
(if possible, at the capacity 
where the motor is most 
heavily loaded).

For maximum current, see 
nameplate. 

If the current exceeds the full load current, 
there are the following possible faults:

• Poor connection in leads, possibly in the 

cable joint.

• Too low supply voltage, see item 1.

L
N
PE

Warning

When the pump is taken out of 
operation, it must be ensured that no 
hazardous material is left in the pump/
motor and the riser pipe, which can be 
injurious to persons and the 
environment.

Subject to alterations.

Summary of Contents for SQE-NE Series

Page 1: ...on 12 6 1 General 12 6 2 Assembly of pump part and motor 12 6 3 Removal of non return valve 12 6 4 Fitting the cable plug to the motor 13 6 5 Fitting the cable guard 13 6 6 Cable sizing 14 6 7 Fitting...

Page 2: ...ator As a minimum the generator output must be equal to the motor P1 kW 10 Starting current The motor starting current is equal to the highest value stated on the motor nameplate Power factor PF 1 Mot...

Page 3: ...ng a screwdriver or a similar tool 4 Inject motor liquid into the motor with a filling syringe or the like 5 To allow possible air to escape move the motor from side to side 6 Refit the filling plug a...

Page 4: ...arked with the following symbol Supply voltage 1 x 200 240 V 10 6 50 60 Hz PE The current consumption can only be measured by means of a true RMS instrument If other instruments are used the value mea...

Page 5: ...be used on the clamping faces of the pump part See fig 6 Fig 6 When pump part and motor have been assembled correctly there must not be a clearance between pump part and motor 6 3 Removal of non retur...

Page 6: ...earance between the motor and the cable plug 6 5 Fitting the cable guard To fit the cable guard proceed as follows 1 Make sure that the submersible drop cable lies flat in the cable guard 2 Place the...

Page 7: ...Fitting the submersible drop cable It is recommended to join the submersible drop cable and the motor cable by means of a Grundfos cable termination kit type KM For larger cross sections please contac...

Page 8: ...lation depths Maximum installation depth below the static water level 150 metres See fig 11 Minimum installation depths below the dynamic water level Vertical installation During start up and operatio...

Page 9: ...switch and diaphragm tank during starting will be lower than the pump cut in pressure set on the pressure switch pcut in This lower pressure is called minimum pressure pmin pmin is equal to the desir...

Page 10: ...ce tools are available from Grundfos The Grundfos Service Manual is available on request The pumps can be serviced at a Grundfos service centre 9 1 Contaminated pumps If Grundfos is requested to servi...

Page 11: ...n the electric installation are blown Replace the blown fuses If the new ones blow too the electric installation and the submersible drop cable should be checked b The ELCB or the voltage operated ELC...

Page 12: ...e is defective Replace the riser pipe i Undervoltage has occurred Check the power supply 4 Frequent starts and stops a The differential of the pressure switch between the start and stop pressures is t...

Page 13: ...d neutral Connect the voltmeter to the terminals at the connection The voltage should when the motor is loaded be within the range specified in section 5 Electrical connection Large variations in supp...