13. Technical data

13.1 Operating conditions

* 47 dB(A) is measured in a typical application with pressure 

control mode (2.5 bar (36 psi) and 1 m

3

/h). In non-typical 

applications noise might increase up to 58 dB.

13.2 Mechanical data

Pipe connections are R 1" or NPT 1".

13.3 Electrical data

13.4 Dimensions and weights

14. Disposing of the product

This product has been designed with focus on the disposal and 
recycling of materials. The following disposal values apply to all 
variants of Grundfos SCALA2 pumps:
• minimum 85 % for recycling
• maximum 10 % for incineration
• maximum 5 % for depositing.
Values are percent of total weight.
This product or parts of it must be disposed of in an 
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company 

or service workshop.

See also end-of-life information on 
www.grundfos.com/product-recycling.

Temperature

[°C (°F)]

Maximum ambient temperature:

1 x 208-230 V, 60 Hz:

45 (113)

1 x 115 V, 60 Hz:

45 (113)

1 x 200-240 V, 50/60 Hz: 55 (131)

Maximum liquid temperature:

45 (113)

Pressure

[bar (psi)]

Maximum system pressure:

10 (145)

Maximum inlet pressure:

6 (87)

Other operating data

Maximum head:

45 m (147 ft)

IP rating:

X4D (outdoor installation)

Pumped liquid:

Clean water

Noise level:

< 47 dB(A)*

Type

Supply 

voltage [V]

Frequency 

[Hz]

I

max. 

[A]

P1

[W]

Stand-by 

power 

[W]

SCALA2

1 x 200-240

50/60

2.3 - 2.8 550

2
2
2
2

SCALA2

1 x 208-230

60

2.3 - 2.8 550

2

SCALA2

1 x 115

60

5 - 5.7

560

2

Type

Supply 

voltage [V]

Frequency 

[Hz]

Plug

SCALA2

1 x 200-240

50/60

IEC, type E&F

IEC, type I

IEC, type G

None

SCALA2

1 x 208-230

60

NEMA 6-15P

SCALA2

1 x 115

60

IEC, type B, NEMA 5-15P

T

M

06

 33

0

5

 51

14

Type

H1

[mm]

[inch]

H2

[mm]

[inch]

H3

[mm]

[inch]

W1

[mm]

[inch]

L1

[mm]

[inch]

Weight

[kg]

[lbs]

SCALA2

302

11.9

234

9.2

114

4.5

193

7.6

403

15.9

10
22

Summary of Contents for SCALA Series

Page 1: ...SCALA Installation and operating instructions GRUNDFOS INSTRUCTIONS http waterheatertimer org Water heater recirculation system html...

Page 2: ...9 8 Setting the product 10 8 1 Setting the outlet pressure 10 8 2 Locking and unlocking the operating panel 10 8 3 Expert settings SCALA2 10 8 4 Resetting to factory settings 11 9 Servicing the produ...

Page 3: ...1 25 bar 18 psi In case of suction lift of more than six metres the pipe resistance on the outlet side must be at least two metres water column or 3 psi at any given flow in order to obtain optimum op...

Page 4: ...f the flexible hose Fig 4 How to reduce noise in the installation 3 3 5 Installation examples Fittings hoses and valves are not supplied with the pump We recommend to follow the installation examples...

Page 5: ...ction lift is 8 m 26 ft H2 Inlet pipe must be submersed at least 0 5 m 1 64 ft TM06 4348 4117 Pos Description 1 Highest tapping point 2 Pipe hangers 3 Isolating valve 4 Flexible hoses 5 Drain to sewer...

Page 6: ...ertain that the pump is connected only to a properly grounded grounding type receptacle protective earthing If national legislation requires a Residual Current Device RCD a Ground Fault Circuit Interr...

Page 7: ...ent of an internal leakage occurs the liquid will be drained through the bottom of the pump Install the pump in such a way that no undesirable collateral damage can arise 5 Handling and storing the pr...

Page 8: ...temperature 13 Minimum and maximum rated power 14 Model 15 Voltage and frequency 16 Approvals 17 Minimum and maximum rated current DK 8850 Bjerringbro Denmark SCALA2 3 45 AKCHDE Model A 200 240V 50 60...

Page 9: ...e cause has disappeared or been remedied See section 8 3 3 Auto reset For further information about system status see section 12 Fault finding the product TM06 3301 5114 SCALA2 Function On off Increas...

Page 10: ...tpoint The pump will lower the setpoint to either 4 5 3 5 or 2 5 bar 65 51 or 36 psi The self learned setpoint is indicated on the operating panel by one flashing green light After every 24 hours the...

Page 11: ...bottom and can easily be removed and cleaned with a stiff brush See fig 19 Clean the insect filter once a year or as needed Fig 19 Insect filter 9 1 2 Inlet and outlet valves The pump is maintenance f...

Page 12: ...uct 4 The pump will remember the controller settings even if it is turned off 10 1 Deblocking the pump The end cover incorporates a plug which can be removed by means of a suitable tool This makes it...

Page 13: ...reset function in the service menu Grundfos Eye Indication Description No lights are on The power is off The pump is not running Two opposite green indicator lights running in the direction of rotatio...

Page 14: ...completely or partly open position Clean repair or replace the non return valve See section 9 Servicing the product 2 The pump is running a Leakage from the pipe system or the non return valve is not...

Page 15: ...ump but it runs only for a few seconds Yes a Dry running or water shortage Check the water source and prime the pump Yes b The inlet pipe is blocked by impurities Clean the inlet pipe Yes c The foot o...

Page 16: ...ontact the nearest Grundfos company or service workshop See also end of life information on www grundfos com product recycling Temperature C F Maximum ambient temperature 1 x 208 230 V 60 Hz 45 113 1...

Page 17: ...8 5005 Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznes...

Page 18: ...8564 The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos Holding...

Reviews: