background image

English (GB)

12

To remove the outlet non-return valve, follow the steps 
below:

1. Turn off the power supply and disconnect the power plug.
2. Shut off the water source.
3. Open a tap to release the pressure in the pipe system.
4. Close the isolating valves and/or drain the pipes.
5. Gradually open and remove the priming plug. See fig. 

20

 (5). 

The plug and non-return valve are one unit.

6. Clean the non-return valve with warm water and a soft brush.
7. Assemble the components in reverse order.

Fig. 21

Outlet and inlet non-return valves

9.2 Customer service information

For further information on service parts, see Grundfos Product 
Center on www.product-selection.grundfos.com.

9.3 Service kits

For further information on service kits, see Grundfos Product 
Center on www.grundfos.com.

10. Starting up the product after standstill 

1. Check that the pump is not blocked by following the 

instructions in section 

10.1 Deblocking the pump

.

2. If the pump has been drained, it must be filled with liquid 

before startup. See sectio

4.1 Priming the pump

.

3. Start up the pump. Follow the instructions in section 

4. Starting up the product

.

4. The pump will remember the controller settings even if it is 

turned off.

10.1 Deblocking the pump

The end cover incorporates a plug which can be removed by 
means of a suitable tool. This makes it possible to deblock the 
pump shaft if it has seized up as a result of inactivity.

Fig. 22

Deblocking the pump

11. Taking the product out of operation 

If the pump is taken out of operation for a period of time, for 
example during the winter, it must be disconnected from the 
power supply and placed in a dry location.
Proceed as follows:
1. Stop the pump by means of the on/off button 

.

2. Disconnect the power supply.
3. Open a tap to release the pressure in the pipe system.
4. Close the isolating valves and/or drain the pipes.
5. Gradually loosen the priming plug to release the pressure in 

the pump.

6. Remove the drain plug to drain the pump. See fig. 

23

.

7. We recommend to store the pump indoors in a dry location. 

Due to humidity, the disconnected pump must not be left 
outside for a longer period of time.

Fig. 23

Draining the pump

TM

06

 43

31

 19

15

Outlet non-return valve

Inlet non-return 
valve

DANGER
Electric shock

Death or serious personal injury
- Switch off the power supply before starting any 

work on the product. Make sure that the power 
supply cannot be accidentally switched on.

TM

06

 42

02

 16

15

TM

06

 42

03

 16

15

Summary of Contents for SCALA Series

Page 1: ...SCALA Installation and operating instructions GRUNDFOS INSTRUCTIONS http waterheatertimer org Water heater recirculation system html...

Page 2: ...9 8 Setting the product 10 8 1 Setting the outlet pressure 10 8 2 Locking and unlocking the operating panel 10 8 3 Expert settings SCALA2 10 8 4 Resetting to factory settings 11 9 Servicing the produ...

Page 3: ...1 25 bar 18 psi In case of suction lift of more than six metres the pipe resistance on the outlet side must be at least two metres water column or 3 psi at any given flow in order to obtain optimum op...

Page 4: ...f the flexible hose Fig 4 How to reduce noise in the installation 3 3 5 Installation examples Fittings hoses and valves are not supplied with the pump We recommend to follow the installation examples...

Page 5: ...ction lift is 8 m 26 ft H2 Inlet pipe must be submersed at least 0 5 m 1 64 ft TM06 4348 4117 Pos Description 1 Highest tapping point 2 Pipe hangers 3 Isolating valve 4 Flexible hoses 5 Drain to sewer...

Page 6: ...ertain that the pump is connected only to a properly grounded grounding type receptacle protective earthing If national legislation requires a Residual Current Device RCD a Ground Fault Circuit Interr...

Page 7: ...ent of an internal leakage occurs the liquid will be drained through the bottom of the pump Install the pump in such a way that no undesirable collateral damage can arise 5 Handling and storing the pr...

Page 8: ...temperature 13 Minimum and maximum rated power 14 Model 15 Voltage and frequency 16 Approvals 17 Minimum and maximum rated current DK 8850 Bjerringbro Denmark SCALA2 3 45 AKCHDE Model A 200 240V 50 60...

Page 9: ...e cause has disappeared or been remedied See section 8 3 3 Auto reset For further information about system status see section 12 Fault finding the product TM06 3301 5114 SCALA2 Function On off Increas...

Page 10: ...tpoint The pump will lower the setpoint to either 4 5 3 5 or 2 5 bar 65 51 or 36 psi The self learned setpoint is indicated on the operating panel by one flashing green light After every 24 hours the...

Page 11: ...bottom and can easily be removed and cleaned with a stiff brush See fig 19 Clean the insect filter once a year or as needed Fig 19 Insect filter 9 1 2 Inlet and outlet valves The pump is maintenance f...

Page 12: ...uct 4 The pump will remember the controller settings even if it is turned off 10 1 Deblocking the pump The end cover incorporates a plug which can be removed by means of a suitable tool This makes it...

Page 13: ...reset function in the service menu Grundfos Eye Indication Description No lights are on The power is off The pump is not running Two opposite green indicator lights running in the direction of rotatio...

Page 14: ...completely or partly open position Clean repair or replace the non return valve See section 9 Servicing the product 2 The pump is running a Leakage from the pipe system or the non return valve is not...

Page 15: ...ump but it runs only for a few seconds Yes a Dry running or water shortage Check the water source and prime the pump Yes b The inlet pipe is blocked by impurities Clean the inlet pipe Yes c The foot o...

Page 16: ...ontact the nearest Grundfos company or service workshop See also end of life information on www grundfos com product recycling Temperature C F Maximum ambient temperature 1 x 208 230 V 60 Hz 45 113 1...

Page 17: ...8 5005 Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznes...

Page 18: ...8564 The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos Holding...

Reviews: