5.22 Empty tank (alarm)
The alarm function can be set to "AUT. RES." or
"MAN. RES.". This function is used when the level
sensor indicates "EMPTY".
The alarm can be reset automatically (AUT. RES.) or
manually (MAN. RES.).
For more information about other alarm functions,
see section
5.6 Alarm output and indicator lights
.
5.23 Measuring units
It is possible to select metric units (litre/millilitre) or
US units (gallons).
Metric measuring units:
•
In manual and analog modes
, set the quantity
to be dosed in litres per hour (l/h) or millilitres per
hour (ml/h).
•
In pulse mode
, set the quantity to be dosed in
ml/pulse. The actual capacity is indicated in litres
per hour (l/h) or millilitres per hour (ml/h).
•
For calibration
, set the quantity to be dosed in
ml per 100 strokes.
•
In timer and batch modes
, set the quantity to be
dosed in litres (l) or millilitres (ml).
•
Under the "QUANTITY" menu item in the
"COUNTERS" menu, the dosed quantity is
indicated in litres.
US measuring units:
•
In manual and analog modes
, set the quantity
to be dosed in gallons per hour (gph).
•
In pulse mode
, set the quantity to be dosed in
ml/pulse. The actual capacity is indicated in
gallons per hour (gph).
•
For calibration
, set the quantity to be dosed in
ml per 100 strokes.
•
In timer and batch modes
, set the quantity to be
dosed in gallons (gal).
•
Under the "QUANTITY" menu item in the
"COUNTERS" menu, the dosed quantity is
indicated in US gallons (gal).