Explanation 

 

Current flow rate 

The current flow rate is displayed as a numerical value and in the 
form of a "tachometer" (blue-coloured circle segments). If the 
nominal flow of the system is exceeded, the circular segments 
appear in red. 

 

Function 

The selected mode of operation appears in a green circle segment. 

 

Perform maintenance  

since … days 

Yellow symbol 

Maintenance due! 

Notify Grünbeck's technical service / authorised service company. 

 

Leak at the  

softliQ installation location 

Yellow symbol (not with softliQ:SD18) 

Check system location (detection via water sensor) for water 
leakage and close main valve of domestic water installation if 
necessary. 

 

… days 

Yellow symbol (not with softliQ:SD18) 

The supply of regeneration salt is running low. The expected time 
for the salt to last in days is displayed. Refill salt tablets. 

 

Red symbol 

The water softener is not working properly. 

1. 

Refill salt tablets. 

2. 

Wait for 10 minutes. 

3. 

Start a manual regeneration (refer to chapter 6.3). 

 

Red symbol 

The water softener is not working properly. There is a fault (refer to 
chapter 8). 

 

Wi-Fi symbol 

This is displayed when there is a Wi-Fi connection with a router. 

 

LAN symbol 

This is displayed when there is a LAN connection established with 
a router. 

 

Cloud symbol 

Displayed when the connection to the Grünbeck Cloud is 
established. 

 

Summary of Contents for softliQ:SD Series

Page 1: ...We understand water Water softener softliQ SD Operation manual ...

Page 2: ...s operation manual Without the written consent of Grünbeck Wasseraufbereitung GmbH no part of this manual may be reproduced in any way nor may any part be processed duplicated or distributed using electronic systems Non compliance of the aforementioned requirements shall be subject to compensation Subject to technical modifications by Grünbeck Wasseraufbereitung GmbH Translation of the original op...

Page 3: ...5 Start up 25 5 1 How to start up the product 25 5 2 Handing over the product to the owner user 34 6 Operation 35 6 1 Touch display 35 6 2 Menu structure 38 6 3 Connection to Grünbeck Cloud 41 6 4 Refilling salt tablets 46 6 5 Starting a manual regeneration 47 6 6 Determining and entering the water hardness 47 6 7 Select regeneration time 49 6 8 Set the blending valve 49 6 9 Installer level code 0...

Page 4: ...al safety as well as to avoid damage to property This symbol identifies information and instructions that you must comply with in order to avoid damage to property This symbol identifies important information about the product or its handling This symbol identifies work that is only allowed to be carried out by a specialist installer In Germany the installation company must be registered in an ins...

Page 5: ...g instruction multi step and chronological sequence of action steps important 1 First action a first step b second step 2 Second action Result after a handling instruction Result Lists List item List sub item Menu paths Status level Menu level Submenu Display texts Display text Operating elements Button key 1 6 Validity of the instruction This instruction applies to the following products Water so...

Page 6: ...available whenever necessary Item Designation Item Designation 1 Observe operation manual 2 Disposal information 3 SVGW test mark 4 DVGW test mark 5 CE mark 6 Nominal pressure 7 Operating pressure 8 Ambient temperature 9 Water temperature 10 Rated voltage range frequency 11 Rated load 12 Protection protection class 13 Product designation 14 QR code 15 Data matrix code 16 Order no 17 Serial no Over...

Page 7: ...upply Safety devices must never be removed bridged or otherwise tampered with Do not operate any products which have a damaged power supply cable This can lead to injuries due to electric shock Have damaged power supply cables replaced without delay Mains cables may only be replaced by the manufacturer or by authorised personnel Observe the maintenance intervals refer to chapter 7 Failure to compl...

Page 8: ...ollowing regulations and directives amongst others during installation start up and maintenance Statutory regulations on environmental protection Provisions of the employers liability insurance companies DIN EN 806 Specifications for installations inside buildings conveying water for human consumption VDI 6023 Part 5 7 Specifications for installations inside buildings conveying water for human con...

Page 9: ...uct explained to you by the specialist installer Only perform activities described in this manual Do not carry out any activities that are explicitly marked for a specialist installer Only use this product as intended Make sure that the required inspection and maintenance work is carried out Keep this instruction 2 6 Permitted regenerant softliQ water softeners are only allowed to be operated with...

Page 10: ...nd connected water carrying systems from scaling or from malfunctions and damage caused by scaling The water softener softliQ SD18 is designed for the continuous supply of 1 to 2 family homes max 4 persons with soft water The water softener softliQ SD21 is designed for the continuous supply of 1 to 4 family homes max 9 persons with soft water The water softener softliQ SD23 is designed for the con...

Page 11: ... for soft water 6 Control display 7 Brine tank lid 8 Salt supply display sensor 9 Illuminated LED ring 10 Cover for connections customer interface 11 Water connection pipes 12 Housing of technical equipment upper part 13 Housing of technical equipment lower part 14 Brine tank 15 Brine valve 16 Sieve bottom 17 Exchanger tank 18 Control valve 19 Water test kit total hardness 20 Water sensor Not with...

Page 12: ...his reaction is called ion exchange The calcium and magnesium ions are retained in the exchanger Soft water without calcium and magnesium ions but containing sodium ions leaves the exchanger This process continues until no more sodium ions are available The ion exchanger resin is exhausted The exchange can be reversed if a large amount of sodium ions is added The exchanger is rinsed with brine wat...

Page 13: ...eriod where usually no water is consumed The point of regeneration can also be set at a fixed time Should water be required during the regeneration process non softened water is available During each regeneration only the used up system capacity is regenerated and only as much salt is used as necessary No later than after 4 days without regeneration the system releases a complete regeneration as r...

Page 14: ...nated LED ring The illuminated LED ring is used as a visual signal in water treatment operation and fault In the standard setting the illuminated LED ring behaves as follows Is illuminated during water treatment Is illuminated during operation of the control unit Intermittent flashing in case malfunctions do occur Intermittent flashing in case of pre alarm salt supply The illuminated LED ring can ...

Page 15: ...for corrosion protection or to stabilise the total hardness Safety device protectliQ A20 126 400 Product for protection against water damage in one and two family homes For other sizes please inquire Regeneration water delivery pump 188 800 To discharge the regeneration water into drain pipes located at a higher level Only suitable for softliQ SD23 and softliQ MD Drain connection DN 50 188 875 For...

Page 16: ...87 875 To easily branch off a 0 dH 0 f 0 mol m pipe e g for a separate pipe for technical applications etc Hall cable with clip and pulse division softliQ EXADOS GSX VGX 119 645 Hall cable with clip and pulse division softliQ EXADOS VFR VGR 119 642 For connecting to an EXADOS dosing computer provided by the client softliQ insulation set 188 870 For professional insulation of the connection equipme...

Page 17: ...tworking Grünbeck products 3 iQ Comfort 2 for networking Grünbeck products 4 Water sensor digital input If another function is required for the digital input the water sensor must be disconnected Cables LiYY 2x0 5 mm or comparable should be used as connecting line A larger line cross section is unsuitable Water sensor pin assignment digital input Terminal top terminal middle water sensor Terminal ...

Page 18: ...it board Item Description Item Description 1 Protection against contact 2 Fault signal contact upper two terminals max 230 V max 1 A factory setting N C 3 Programmable output lower two terminals e g connection of the regeneration water delivery pump max 230 V max 1 A factory setting regeneration water delivery pump 2 Use the following connection cables for connection to the fault alarm contact or ...

Page 19: ...install these systems Item Description Item Description 1 Safety device protectliQ 2 Drinking water filter pureliQ KD 3 Garden water pipe 4 Water withdrawal point 5 EXADOS dosing computer 6 softliQ insulation set 7 Drain connection DN 50 acc to DIN EN 1717 The connection block can be installed horizontally or vertically in the drinking water system No dosing can be connected in a vertical installa...

Page 20: ...er filter and if required a pressure reducer e g fine filter pureliQ KD upstream of the product A shock proof socket is required within a distance of approx 1 2 m of the system The socket requires a permanent power supply and must not be connected to light switches emergency heating switches or similar devices A drain connection DN 50 must be available to discharge the regeneration water There mus...

Page 21: ... of supply Item Description Item Description 1 Water softener completely pre assembled 2 2 Connection hoses 3 Water test kit total hardness 4 Operation manual 5 Connection block incl 2 inserts 2 union nuts 2 gaskets Check the scope of supply for completeness and damage ...

Page 22: ... open the two valves on the connection block during start up Only carry out the leakage test during start up 4 3 1 Installing connection block 1 Install the water meter screw connection into the pipe 2 Check the flow direction given on site The direction of flow is indicated by an arrow on the connection block 3 Make sure that the strainer insert is inserted on the inlet side 4 Mount the connectio...

Page 23: ...w both the screws at the side on the upper part of the housing for technical equipment 2 Remove the upper part of the housing for technical equipment 3 Observe the flow direction indicated by arrows on the connection block and on the control valve 4 Mount the connection hoses with a suitable tool ...

Page 24: ...the flushing water hose regeneration water flows out under pressure 3 Shorten the overflow hose diameter 16 mm to the required length 4 Run the overflow hose to the drain with a downward slope 5 Make sure there is a free outlet to the drain in accordance with the standard 6 Fasten the overflow hose If the flow pressure is at least 3 bar the flushing water hose can be routed up to 2 m above the flo...

Page 25: ...en display see chapter 6 Use the or buttons to navigate through the program Press to go to the previous menu level With you confirm the selection and move to the next menu level 5 1 1 Initial start up and automatic start of the start up program 1 Keep salt tablets refer to chapter 2 6 ready 2 Plug in the mains plug 3 Select the desired language touch the corresponding flag 4 Select the continent w...

Page 26: ...ogram 1 Check the correct system connection 2 Select the drain connection used 3 Check whether the lines to the drain connection have been laid with a gradient 4 Place the water sensor flat on the floor 5 Fill salt tablets into the brine tank refer to chapter 6 3 do not fill in water ...

Page 27: ...d water test kit refer to chapter 6 6 8 Type in the value for the raw water hardness You can change the value at a later time refer to chapter 6 6 After the set value has been confirmed the automatic positioning of the control valve starts Item Description Item Description 1 Shut off valve for raw water 2 Blending valve 3 Locking screw Torx 20 required 4 Shut off valve for soft water 5 Dosing conn...

Page 28: ...hut off valve 10 Open the soft water shut off valve Water flows through the flushing water hose to the drain This is normal during start up 11 Start the ventilation program There is an automatic sequence of 9 program steps This is followed by a 5 step functional check ...

Page 29: ...2 Adjust the blending valve as follows a Loosen the locking screw on the blending valve b Close the blending valve completely turn to the right 13 Remove cold water at the water draw off point 14 Measure the soft water hardness refer to chapter 6 6 ...

Page 30: ...int completely let the water run 17 Remove cold water and measure the soft water hardness 18 Set the soft water hardness using the blending valve Turning to the right reduces the soft water hardness turning to the left increases it Exception for Austria In Austria soft and water must have a soft water hardness of min 8 4 dH ...

Page 31: ...softliQ SD 19 Observe the max sodium concentration refer to chapter 12 1 20 Fix the locking screw 21 Type the set soft water hardness into the display 22 Close the water withdrawal point 23 Look and check the connection points for leaks ...

Page 32: ...Start up 32 80 BA_TD3 BS001en_014_softliQ SD 24 Start the test regeneration The test regeneration lasts approx 12 minutes Let the test regeneration run The start up program is finished ...

Page 33: ...g refer to chapter 13 This completes the start up 5 1 3 Manual start of the start up program Menu level Start up Press and hold for 2 seconds Follow the instructions on the display The sequence of the steps is analogous to the automatic start up program The start up program cannot be started while a regeneration is running ...

Page 34: ...the water softener works Use the manual to brief the owner user and answer any questions Inform the owner user about the need for inspections and maintenance Inform the owner user about the influence of water hardness on the dosage rate of detergents and cleaning agents Hand over all documents to the owner user for storage ...

Page 35: ...r supply if necessary 6 1 Touch display 6 1 1 Basic display The touch display is switched off by default It is activated by tapping on the touch display After a 2 minute pause the control unit returns to the basic display the touchscreen display switches off Parameters that have not been saved are discarded Item Description Item Description 1 Menu level always displayed 2 Work area information dis...

Page 36: ...ss You can enter the current values in this menu refer to chapter 6 6 Start up In this menu you can start the automatic start up program refer to chapter 5 1 6 1 3 Information display Figure Explanation Blue symbol The water softener is working properly The system capacity declines from the top downwards between 2 regenerations One bar corresponds to 20 The bright bars indicate the available syste...

Page 37: ...m location detection via water sensor for water leakage and close main valve of domestic water installation if necessary days Yellow symbol not with softliQ SD18 The supply of regeneration salt is running low The expected time for the salt to last in days is displayed Refill salt tablets Red symbol The water softener is not working properly 1 Refill salt tablets 2 Wait for 10 minutes 3 Start a man...

Page 38: ...ters are grouped together onto tabs under the header Tap the tab to open the corresponding page If necessary you can switch between the tabs with the or buttons 6 2 Menu structure Values that can be selected or changed are shown in italics Menu Menu items Values settings Information Basic display Refer to chapter 6 1 1 System data Flow rate Raw water hardness Capacity figure Counter readings date ...

Page 39: ...synchronisation URL NTP server Cloud connection Wi Fi LAN connection network status Cloud connection Allow connection to Grünbeck Cloud Linking with Grünbeck Cloud user account URL Cloud URL certificate Wi Fi LAN connection Network type router connection Automatic IP address DHCP Automatic WLAN connection WPS Wi Fi search Found Wi Fi networks Wi Fi password Network status Parameter value display o...

Page 40: ...tware update Automatic Manual Save settings profile no yes The parameter settings are saved here as a Private profile in the Grünbeck Cloud Load settings profile Private profile Installer profile Load history stored in Cloud Start Manual update Software update Press and hold button for 2 seconds to check for updates Reset factory settings Start Device info Software version hardware version serial ...

Page 41: ...uct app on a mobile device Allow Grünbeck Cloud connection in the control unit Connect softliQ to router via LAN or Wi Fi Setting up a user account in the Grünbeck Cloud As soon as a user account has been created via the Grünbeck myProduct app and the anonymous data is linked to your user account the data is personalised as defined by the Data Protection Act 6 3 1 Installing Grünbeck myProduct app...

Page 42: ...The symbol appears in the basic display as soon as the connection to the Grünbeck Cloud is established The following parameters are used for information or adaptation in case of network problems Menu items Settings remarks IP address Normally assigned automatically by the router DHCP server Can be changed manually must be different from the other IP addresses already on the network Must be set in ...

Page 43: ...nctions are always available Do not disconnect the power while a firmware download and processing are in progress max 20 minutes 6 3 3 Establishing connection with router Connect via LAN only possible with softliQ SD21 and SD23 You need an Ethernet patch cable that is not included in the scope of delivery 1 Unscrew both the screws at the side on the upper part of the housing for technical equipmen...

Page 44: ...housing of the technical equipment The Ethernet patch cable is routed out of the housing with the connection hoses 8 Fasten the upper part of the housing of technical equipment on the side with the screws 9 Plug the Ethernet patch cable into the LAN connector of your router Menu level Settings Wi Fi LAN connection 10 Select Network type router connection 11 Select LAN 12 Leave the checkbox activat...

Page 45: ...e Wi Fi connection is established within approx 2 minutes without WPS function 1 Select Start on the control unit at Wi Fi search After a few seconds the max 10 Wi Fi networks with the best receivable signal quality appear 2 Select your Wi Fi router from this list 3 Confirm with 4 Enter your Wi Fi password The symbol appears in the basic display as soon as the Wi Fi connection to the router is est...

Page 46: ...come a water expert faq 6 4 Refilling salt tablets The level of salt tablets in the brine tank must always be higher than the water level The water level is normally approx 1 cm above the sieve bottom 1 Open the brine tank lid The brine tank lid on the softliQ SD21 and softliQ SD23 contains the sensor for the salt supply display This sensor does not work with laser light so it is safe for the eyes...

Page 47: ...l can be converted from f Item Description Item Description 1 Test tube 2 Titration solution 6 6 1 Taking a water sample Open the water withdrawal point for cold water fully A flow rate between 400 l h and 600 l h must be attained in order to produce a correct result You can read the flow rate on the touch screen display 1 Open a water withdrawal point for cold water a In order to take a raw water...

Page 48: ...rops corresponds to the degree of hardness in dH or f Example Test tube filled up to the dH mark 6 drops 6 dH Test tube filled up to the f mark 6 drops 6 f 6 6 3 Determining the water hardness in mol m mmol l 1 Determine the water hardness in f as described 2 Divide the value in f by 10 The water hardness in f divided by 10 corresponds to the degree of hardness in mol m mmol l Example 6 drops 6 f ...

Page 49: ...th 6 8 Set the blending valve The blending valve may only be set with running water approx 400 600 l h which is about the flow rate of a fully opened water tap Recommended soft water hardness 3 6 dH 5 11 f 1 Measure the raw water hardness refer to chapter 6 6 2 Move the blending valve to the middle position 3 Measure the soft water hardness refer to chapter 6 6 4 Set the soft water hardness to the...

Page 50: ...following parameters and values can be changed Menu items Settings remarks Wi Fi access point Page 1 2 Activate deactivate Page 2 2 IP address SSID password Exchanger tank Page 1 2 Flow l h Capacity figure m x dH Remaining capacity m Regeneration step Page 2 2 Regeneration flow rate l h Last regeneration date time Above xxx Flow rates indication only Peak flow value m h for xxxxx min Water volumes...

Page 51: ...regeneration time Regeneration only takes place if required Weekly timer Mon Sun Time of the regeneration on each day of the week factory setting Mon Fri 7 00 am Save settings profile none factory setting yes Save all current parameter settings of the control unit in the Grünbeck Cloud so that you can load them back into the control unit later if necessary The parameter settings are saved here as ...

Page 52: ...applied and there is no fault N O Contact closed in the event of a malfunction Programmable input function Leakage detection factory setting If a leakage is detected at the installation site of the softliQ system via the water sensor the message Leakage at the softliQ installation site is displayed Regeneration lock The regeneration lock is active as long as the contact at the programmable input i...

Page 53: ...sures trouble free hygienic operation At least once a year the water softener must be serviced by Grünbeck s technical service authorised service company or by specialist installers trained by Grünbeck A maintenance contract ensures that all the required maintenance work will be performed in due time Only use genuine spare and wearing parts from Grünbeck 7 1 Cleaning Only clean the outside of the ...

Page 54: ...4 Check the control valve to the drain for leaks No water is allowed to drip out of the flushing water hose during operation The water softener is in operation when the blue symbol is displayed in information level 1 refer to chapter 6 1 7 3 Intervals For this purpose DIN EN 806 5 recommends a semi annual and an annual maintenance Operation Interval Execution Inspection 2 months Visual inspection ...

Page 55: ...ts in the brine tank must always be higher than the water level The water level is normally approx 1 cm above the sieve bottom 3 Evaluate the salt consumption subject to the water volume consumed 4 Check the salt condition salt must not be lumpy Break up incrustations with a suitable tool 5 Check the function of the water sensor by immersing the water sensor in water or alternatively bridge it wit...

Page 56: ...ry Maintenance work 10 Check the hose connections for leaks and damage 11 Check the soft water meter for pulse emission current flow during operation refer to chapter 6 1 12 Check all cables and connections for damage and a firm seat 13 Check the injector and injector sieve for dirt and clean them if necessary 14 Check the brine filling orifice in the brine connection angle red 15 Check the brine ...

Page 57: ...onsumables Product Order no Regeneration salt tablets 25 kg acc to DIN EN 973 type A 127 001 Water test kit Total hardness 170 187 7 6 Spare parts For spare parts and consumables please contact your local representative You can find these on the Internet at www gruenbeck de ...

Page 58: ... are listed below Control valve Gaskets set of discs injector and chlorine cell Item Designation Item Designation 1 Injector with circlip 2 Chlorine cell with circlip 3 Regeneration disc pair with flow stabiliser Brine valve Gaskets and electrodes Item Designation Item Designation 1 Seal 2 Electrodes ...

Page 59: ...pter 1 7 handy 8 1 Display messages 1 Acknowledge the display signal with rectify 2 Watch the display 3 If the fault occurs again compare the display message with the following table 8 1 1 Warning messages yellow symbols Display shows Explanation Remedy Perform maintenance since days Only displayed if maintenance interval is activated Notify Grünbeck s technical service authorised service company ...

Page 60: ... chapter 6 3 Confirm with Rectify Water pressure too low Increase the flow pressure to min 2 0 bar Chlorine cell worn Brine filling orifice injector injector sieve or brine valve clogged Notify Grünbeck s technical service authorised service company Malfunction at the drive to the regeneration control valve Step monitoring of regeneration motor or connecting cable defective Notify Grünbeck s techn...

Page 61: ...e exceeded Injector clogged or raw water pressure too low Notify Grünbeck s technical service authorised service company Nominal flow rate exceeded Only displayed if monitoring was activated by the specialist installer System is being operated with excessive flow rates Reduce the flow rate If the error persists notify Grünbeck s technical service authorised service company Water loss to drain Wate...

Page 62: ...r filling the brine tank has been triggered Check whether the raw water shut off valve is open Confirm with Rectify Repeat the start up Error during start up chlorine current too low Flow monitoring during test regeneration has been triggered Fill the brine tank with salt tablets if you have not already done so Confirm with Rectify Repeat the start up Error during commissioning referencing Step mo...

Page 63: ...re open Resin beads in the flushing water hose or aerator Defective jet system Notify Grünbeck s technical service authorised service company Water pressure at the withdrawal point too low Pressure loss too high Resin may be polluted by undissolved particles If the problem comes from the water softener contact Grünbeck s technical service authorised service company Start up program When venting st...

Page 64: ... Leave your product connected to electricity and water Should you wish to temporarily shut down your water supply due to a longer period of absence proceed as follows 1 Close the soft water shut off valve 2 Leave the raw water shut off valve open 3 Keep the water softener connected to power The product remains in an operating state which is considered to be safe with regard to hygiene and which is...

Page 65: ...ter withdrawal point 3 Wait for a few seconds The pressure in the product and the pipe network is being relieved 4 Close the water withdrawal point 5 Disconnect the product from mains 6 Separate the product from the connection hoses Keep a collecting vessel e g a bucket handy to catch escaping water 7 Separate the connection hoses from the connection block 8 Dismantle the connection block 9 Close ...

Page 66: ...t This means that this product or the electric and electronic components are not allowed to be disposed of in the household waste Find out about local regulations on the separate collection of electrical and electronic products Use the collection points available to you for disposing of your product For information on collection points for your product contact your municipality the public waste di...

Page 67: ...m 815 C System depth mm 430 D Connection height of control valve soft water mm 470 E Connection height of control valve raw water mm 510 F Height of safety overflow of brine tank mm 520 G Height with open lid mm 1060 H Installation length without screw connection mm 190 I Installation length with screw connection mm 271 Operating weight approx kg 65 69 73 Shipping weight approx kg 22 24 26 ...

Page 68: ... 8 20 14 36 1 4 3 6 9 23 16 41 1 6 4 1 Capacity per kg of regeneration salt mol kg 6 7 4 5 7 1 4 5 Regeneration time for a complete regeneration min 20 40 Regeneration 1x per day in case of reduction in capacity 50 Filling volumes and consumption data softliQ SD18 softliQ SD21 softliQ SD23 Resin volume l 5 7 5 9 Salt consumption per full regeneration kg 0 15 0 55 0 20 0 80 0 23 0 95 Max capacity o...

Page 69: ... you about the sodium content of your raw water Sample calculation Raw water hardness 28 dH 50 f 5 mmol l Sodium content in the raw water 10 5 mg l Admissible increase of the sodium content by softening 200 mg l 10 5 mg l 189 5 mg l 189 5 8 2 23 dH 41 f 4 1 mmol l The raw water hardness may be reduced from 28 dH 50 f 5 mmol l to 5 dH 9 f 0 9 mmol l 12 2 Hardness ranges The hardness ranges were cla...

Page 70: ...connection acc to DIN EN 1717 yes no Floor drain available yes no Safety device yes no Regeneration water lifting system yes no Make Dosing yes no Active agent Operating values Water pressure bar Reading of residential water meter m Hardness unit dH f mol m e ppm Raw water hardness measured Raw water hardness set Soft water hardness set Remarks Start up Company Service technician Work time certifi...

Page 71: ...on water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve level electrodes cleaned replaced Brine tank cleaned Salt tablets checked for cleanliness Reference position moved to manually C 005 Suction power of the injector checked during salting 0 1 l in 60 120 s Current at the chlorine cell during...

Page 72: ...on water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve level electrodes cleaned replaced Brine tank cleaned Salt tablets checked for cleanliness Reference position moved to manually C 005 Suction power of the injector checked during salting 0 1 l in 60 120 s Current at the chlorine cell during...

Page 73: ...on water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve level electrodes cleaned replaced Brine tank cleaned Salt tablets checked for cleanliness Reference position moved to manually C 005 Suction power of the injector checked during salting 0 1 l in 60 120 s Current at the chlorine cell during...

Page 74: ...on water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve level electrodes cleaned replaced Brine tank cleaned Salt tablets checked for cleanliness Reference position moved to manually C 005 Suction power of the injector checked during salting 0 1 l in 60 120 s Current at the chlorine cell during...

Page 75: ...on water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve level electrodes cleaned replaced Brine tank cleaned Salt tablets checked for cleanliness Reference position moved to manually C 005 Suction power of the injector checked during salting 0 1 l in 60 120 s Current at the chlorine cell during...

Page 76: ...on water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve level electrodes cleaned replaced Brine tank cleaned Salt tablets checked for cleanliness Reference position moved to manually C 005 Suction power of the injector checked during salting 0 1 l in 60 120 s Current at the chlorine cell during...

Page 77: ...aforementioned system also complies with the following directives and provisions Directive on the Restriction of Hazardous Substances RoHS 2011 65 EC Electrical and Electronic Equipment Ordinance The following harmonised standards have been applied DIN EN 61000 6 2 2006 03 DIN EN 61000 6 3 2011 09 DIN EN 60335 1 2012 10 The following national standards and regulations have been applied DIN 19636 1...

Page 78: ...nated LED ring 14 40 Inspection 53 54 Intervals 54 M Maintenance 53 55 56 Malfunction 14 52 59 Menu structure 38 O Operation 64 P Power mode 13 R Raw water 28 69 Regeneration agent 9 Regeneration water 24 S Salt tablets 9 25 26 46 54 55 Select regeneration time 49 Soft water 10 28 56 Spare parts 57 Starting a manual regeneration 47 Start up 25 36 Start up program 36 System capacity 13 W Wearing pa...

Page 79: ......

Page 80: ...Grünbeck Wasseraufbereitung GmbH Josef Grünbeck Str 1 89420 Hoechstaedt GERMANY For more Information go to www gruenbeck com 49 9074 41 0 49 9074 41 100 info gruenbeck com www gruenbeck com ...

Reviews: