Malfunction
59 | 80
B
A
_
T
D3
-B
S
0
0
1
e
n
_
0
1
4
_
so
ft
liQ
-SD
8
Malfunction
WARNING:
Danger of contaminated drinking water due to stagnation.
● Risk of infectious diseases.
► Have malfunctions remedied immediately.
The water softener softliQ indicates malfunctions on the display. As soon as a fault appears,
the touch-screen display changes to the basic display and remains active until the fault is
rectified.
► If malfunctions cannot be remedied by the instructions given below, contact
Grünbeck's technical service / authorised service company.
► Have your equipment data (refer to chapter 1.7) handy.
8.1
Display messages
1.
Acknowledge the display signal with rectify.
2.
Watch the display.
3.
If the fault occurs again, compare the display message with the following table.
8.1.1
Warning messages (yellow symbols)
Display shows
Explanation
Remedy
Perform maintenance
since … days
Only displayed if
maintenance interval is
activated.
Notify Grünbeck's technical service /
authorised service company.
SD21 and SD23 only:
Leak at the
softliQ installation location
Water sensor has
electrical connection.
Check whether water is leaking.
If necessary, close the main valve of
the house installation.
SD21 and SD23 only:
Salt supply low!
Please refill!
Sufficient for: xy days
(order no. 127 001)
Salt supply low.
Refill salt tablets (refer to
chapter 6.3).
Confirm with Rectify.