16
Maßstab/Scale
Benennung / Title
Material
Name
Datum/Date
Warengruppe
Blatt/Sheet
Gewicht/Weight
Toleranzen / Tolerances: ISO 2768-1 m K
Schaumstoffteile nach DIN 7715 Teil 5 Klasse P2
Dieses Dokument ist Eigentum von:
This document is ownership of:
3/3
Zeichnungsnr. / Drawing no.
Bearb.
Gepr.
Änd./Index
a
J. Niederg.
J. Niederg.
1:1,5
DIN A4
Maße in mm
VK-Artikel-Nr.
Zust.
Änderung
Datum Name Gepr.
LUB-D-1-1
21.11.2017
21.11.2017
5.3
LUB-D-1-1 / LUB-D-1-1-250
LUB-D-1-1's theoretical two outlets per installed pump unit are combined internally. One
outlet is supplied with 0.16 cm³ lubricant per stroke. The outlets are supplied with lubri-
cant one after the other.
LUB-D-1-1 allows to set dosing volume diff erences from outlet 1.1 to outlet 2.1 by indivi-
dual control of the two pump bodies. An explanation of the diff erent control signals can
be found in chapter 8.2.
Number of pump units (PU)
2
Number of outlets
2
Differences in dosing volume per PU
yes