17
Maßstab/Scale
Benennung / Title
Material
Name
Datum/Date
Warengruppe
Blatt/Sheet
Gewicht/Weight
Toleranzen / Tolerances: ISO 2768-1 m K
Schaumstoffteile nach DIN 7715 Teil 5 Klasse P2
Dieses Dokument ist Eigentum von:
This document is ownership of:
3/3
Zeichnungsnr. / Drawing no.
Bearb.
Gepr.
Änd./Index
a
J. Niederg.
J. Niederg.
1:1,5
DIN A4
Maße in mm
VK-Artikel-Nr.
Zust.
Änderung
Datum Name Gepr.
LUB-D-3
21.11.2017
21.11.2017
5.4
LUB-D-3 / LUB-D-3-250
LUB-D-3's theoretical two outlets of the fi rst pump body are internally combined into one
outlet 1.1. One outlet is supplied with 0.16 cm³ lubricant per stroke. The outlets are sup-
plied with lubricant one after the other.
LUB-D-3 allows you to set dosing volume diff erences from outlet 1.1 to outlets 2.1 and
2.2 by controlling the two pump bodies individually. An explanation of the diff erent control
signals can be found in chapter 8.2.
If the two pump units are controlled equally, outlet 1.1 is supplied with twice the
amount of lubricant of outlets 2.1 or 2.2, due to the internal combination of the outlets of
the fi rst pump unit.
Number of pump units (PU)
2
Number of outlets
3
Differences in dosing volume per PU
yes