background image

ZigBee Module

User 

m

anual

Summary of Contents for ZigBee Module

Page 1: ...ZigBee Module User manual ...

Page 2: ...CONTENT User Manual Information 1 Description 2 Setting the ZigBee ID and Channel of the Data Logger 3 Setting the ZigBee Module 4 Installation of ZigBee Module 5 FAQ 6 Technical Data 7 Contact 8 ...

Page 3: ...owever that Growatt reserves the right to make changes without notice and shall not be responsible for any damages including indirect incidental or consequential damages caused by reliance on the material presented Distinguished users thank you very much for your trust in our ZigBee Module product which is developed and manufactured by our R D department We sincerely hope it can satisfy your need ...

Page 4: ...NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause...

Page 5: ...2 Description ZigBee Module is a wireless device used to enable the communication between inverter and data logger The Shine Webbox and Shine Pano serve as the data logger 3 ...

Page 6: ...r and enter 192 168 1 230 in the address bar then you can set the ZigBee ID and Channel via the integrated server of the data logger 4 Note network segment then it is available to get access into the integrated server of the data logger As to more details please refer to the user manual of data logger e g Shine Webbox User Manual Only the IP address of the data logger and the accessing PC are in t...

Page 7: ...between 1000 and 9999 2 Set ZigBee channel In parameter field select Zigbee_channel enter the ZigBee channel within the range between 11 and 25 3 If the parameters of data logger about the ZigBee configuration have been modified the parameters of the ZigBee Module have to be also modified ...

Page 8: ...etup Support ZConfigureV53E exe 2 Connect the ZigBee Module with PC via the configuration Box ZigBee Module corresponds to the side of Configuration Box printed with Module and the RS232 port corresponds to another side of Configuration Box printed with RS 232 3 Operate the ZConfigureV53E exe as following figure ...

Page 9: ...ght click My computer choose Manage Device Manager Ports COM LPT 5 Choose the same COM port with device manager 6 Single click connect If the indicator light turns to green the connection state is OK COM Port ...

Page 10: ...7 Select Zigbee Radio Channel The range of channel is 11 25 The Radio Channel of ZigBee Module shoud be set as the same value of Zigbee_channel configured in the data logger 8 ...

Page 11: ...e same as the Zigbee_ID configured in the data logger If not the connection would fail Enter two values in the input box of PAN ID e g 33 55 Single click SETTING then click READ If it works the success dialog box will pop up If not please set again 9 ...

Page 12: ...then click on connect If PAN ID is still the pre set value the configuration is OK If not please set again Note If you have already set 6 ZigBee Modules one of the 6 Modules should be power on and then you can set another 6 ZigBee Modules 10 1 2 ...

Page 13: ...2 port is compliant with the specification 1 please turn on the DIP switch then plug the ZigBee Module to the inverter directly via the RS232 and lock screw RS 232 1 2 RS 232 11 If the RS232 port is compliant with the specification 2 please pry open the rubber plug in the waterproof cushion then plug the ZigBee Module to the inverter and lock screw ...

Page 14: ...2 Open the Record interface of the data logger If the inverter corresponding to the ZigBee Module has shown in the list the installation is OK 12 ...

Page 15: ...displays FF FE the setting fails Please click on Module Restart Connect and then reset PAN ID refer to chapter4 step 3 7 As an alternative method you could change the value of the PAN ID and channel then reset the data logger and ZigBee Module 3 As to the same one inverter either wireless method or wired method could be chosen as a monitoring scheme If not the data logger couldn t search inverters...

Page 16: ...cation range RS 232 Modbus RTU 300m without obstacle Electrical Data Voltage Power consumption 8V 15V DC 0 5W Operating Conditions Ambient temperature Humidity Degree of protection 20 60 5 95 IP65 General Data Length Width depth Net Weight 135 79 29mm 63g 14 ...

Page 17: ... our products please contact Growatt Growatt New Energy Technology Co Ltd Building B Jiayu Industrial Zone 28 Guanghui Road Longteng Community Shiyan Baoan District Shenzhen P R China 86 755 27471942 service ginverter com www growatt com 15 GR UM 011 01 ...

Reviews: