7
8
Unpacking
4
Please check whether external damage to the goods before unpacking.
After unpacking, please check whether the unit damage or missing parts, if it is
happen, please contact with supplier.
SPH series and accessories as follows:
Item
Description
Quantity
A
SPH inverter
1
B
User Manual
1
C
Paper board(installation guide)
1
D
Communication cable (10m)
1
E
Current sensor( or meter)
1
F
Lead-acid battery temperature sensor
1
G
RJ45 connector
1
H
M6 setscrew
4
I
Wire terminal
12
J
Hex screwdriver
1
K
Battery power terminal
2
E. Battery installation option is not far away from the position of SPH, the length
between SPH and battery should not be more than 1.5m.
F. The ambient temperature should be -25
℃~
60
℃
(-13°F~140°F).
G. SPH can be installed in vertical or lean back on plane, please refer to the below:
H. Installation position shall not prevent access to the disconnection means.
I. In order to ensure machine can run normally and easy to operate, please pay
attention to provide adequate space for SPH, pleases refer to below:
Installation
5
5.1 Basic installation requirements
A. The installation location must be suitable for SPH's weight for a long period time
B. The installation location must conforms with dimension of SPH
C. Do not install the unit on structures constructed of flammable or thermo labile
materials
D. The ingress Protection rate is IP65 (NEMA Type 4X), and SPH can't be enclosed.
Please refer to the below:
90
°
15
°