17
18
Chart 5.13
Chart 5.14
Step 3: Push threaded sleeve on to connection terminal until both are locked tightly.
Step 4:Plug the socket into AC output terminal
,
clockwise rotation to tighten the
socket, counterclockwise rotation to loosen the socket.
The following diagram shows the AC output terminal of the Australian machine
connection steps, EPS output terminal connection steps consistent with the above steps.
AC output terminal and EPS output terminal connection steps as follow:
Step 1: Uninstall the AC terminal as below chart.
Step 2: Thread cables through pressure screw, seal ring, threaded sleeve in sequence,
insert cables into connection terminal according to polarities indicates on it and tighten
the screws.
Step 3: Push threaded sleeve on to connection terminal until both are locked tightly.
Step 4:Plug the socket into AC output terminal until it is locked. Use a flat-blade
screwdriver to hold the buckle and pull out the AC terminal.
Step 5: Plug the AC terminal into the inverter AC port.
Chart 5.15
Chart 5.16
Chart 5.17
Chart 5.18
Chart 5.19