39
40
Chart 6.5
The A line's concluding information as follow:
Ø
Standby state: SPH is in standby state. No error in this state, but for other reasons,
make it in a wait state.
Ø
Normal state: SPH is normal working state.
Ø
Checking state: SPH is in self-check state, if there is no error or warning, SPH will go
to normal state or standby state. Otherwise it will go to fault state.
Ø
Programming state: SPH is in updating firmware state.
Ø
Fault state: SPH has fault information, it will be in stopped operational protection
state.
The B line's information as follow:
In normal, it will turn on page automatically, when pushing the button “UP”, the order
of the paging information as follow:
Note:
Ø
“
Down” control command (if press “up” button, command will go back).
Ø
Workmode depend on the situation. If SPH is normal state, it will show “normal”. If
SPH is standby state, it will show as “standby” etc.
Ø
Some special definitions are explained, for example: Vb means the voltage of
battery. Cb means the capacity of lithium battery (only lithium battery shows this
data). Pm means the monitor power of user.
Chart 6.6
If you choose CEI and used SPH inverter in Italy, SPH inverter have Auto Test function.
How to use the Autotest functions. Please see the annex.
6.4.4 work mode set up
You can enter set up page by long press “enter” for 3S, in this page, you can press
“enter” or “ESC” for 1S to finish the selection, the page shows like following:
WorkMode
Input&Output Para
WorkMode
(Lead acid)Vb:xx.xV
(Lithium)Vb/Cb:xx.xV xxx%
WorkMode
Vpv:xxx/xxxV
WorkMode
Ppv:xxxx/xxxxW
PV1/PV2 voltage
Battery information
WorkMode
Grid_R:xxxV/xxHz
WorkMode
EPS_R:xxxV/xxHz
WorkMode
Po: xx.xkW
GridS information
Output AC Power
EPS-R information
WorkMode
Pbat: (+/-)XXXX W
Battery power
EPS-R output power
WorkMode
Epv_d:xxxx.x KWh
WorkMode
Epv_a:xxxx.x KWh
WorkMode
Ec_d:xxxx.x KWh
WorkMode
Ec_a:xxxx.x KWh
WorkMode
Ed_d:xxxx.x KWh
WorkMode
Ed_a:xxxx.x KWh
WorkMode
SerNo:xxxxxxxxxx
PV1/PV2 today energy
PV1/PV2 total energy
PV1/PV2 input power
BAT Charge_Etoday energy
WorkMode
Pm:
(+/-)XXXX
W
Press up key
Power to grid or to user
To grid is -
To user is +
BAT Charge_Etotal energy
BAT Discharge_Etoday energy
BAT Discharge_Etotal energy
WorkMode
20XX/XX/XX/XX:XX
System Time
WorkMode
Model:xxxxxxxxxx
WorkMode
FW Version:xxxx
WorkMode
Eac_d:xxxx.x KWh
WorkMode
Eac_a:xxxx.x KWh
AC output_Etoday energy
AC output_Etotal energy
WorkMode
Grid_S:xxxV/xxHz
WorkMode
Grid_T:xxxV/xxHz
GridR information
GridT information
WorkMode
EPS_S:xxxV/xxHz
EPS-S information
WorkMode
EPS_T:xxxV/xxHz
EPS-T information
EPS-S output power
EPS-T output power
WorkMode
EPS_R
: xxxx VA
WorkMode
EPS_S
: xxxx VA
WorkMode
EPS_T
: xxxx VA
WorkMode
Per_Load: %
Auto Loop Display
Button operation display
Load ratio
WorkMode
Po: xx.xkVA
Cycle
display 2
times in 6
seconds
Serial number
Machine model
Firmware version
Offline
Online
MasterPower
WorkMode
MCUyaaaXXXXXXXXX
Wait for 6 second
Software version
Basic Parameter
WorkMode
WorkMode
Configuration
WorkMode
Priority
WorkMode
BackUp
Press
“
enter
”
key more than
3 seconds into setup mode
Press
“
down
”
key
to the next item
Press
“
enter
”
key more
than 1 seconds to make sure
Mode Change
WorkMode
ExportLimit
WorkMode
Auto Test
WorkMode
Default Set
WorkMode