U0594061-C
Page 16 / 82
CORFIRST / CORSUN 2 / CORFLOW
EN
1. CERTIFICATION
- Energy labelling (2010/30/EU): from 26/09/2015
In application of the directive and according to the requirements of the EU regulation
No. 812/2013 of 18 February 2013, the information on storage tanks with a volume of less
than or equal to 500 litres is available in appendix B (see page 75)
.
- Eco-design (2009/125/EC): from 26/09/2015
In application of the directive and according to the requirements of EU regulation
no. 814/2013 of 02 August 2013, the technical parameters of storage tanks with a volume
less than or equal to 2,000 litres are available in appendix C (see page 77).
For the purposes of transparency, the data on the rest of the range is available in appendix
D (see page 82).
2. DESCRIPTION OF STORAGE TANKS
The
CORFIRST
tanks feature one coil integrated into their upper section that transfers the
heat collected by the solar sensors to the domestic hot water of the tank.
The
CORSUN 2
tanks feature 2 integrated coils: the lower coil transfers the heat collected
by the solar sensors to the domestic hot water of the tank and the upper coil transfers the
heat from backup energy when there is insufficient solar energy.
The
CORFLOW
tanks feature 1 high output coil for connection to a boiler.
CORFIRST, CORSUN 2 and CORFLOW tanks have external rust protection with a layer of
paint.
Maximum water temperature in use: 95°C
Service pressure: 8 bar
The storage tanks' thermal insulation consists of:
-
for the M0 version
, a rigid grey sheet-metal casing over 100 mm of glass wool,
-
for the M1 version
, a flexible insulating casing consisting of 100 mm of glass wool covered
with a flexible PVC envelope (non-flammable),
-
for the TOP NC version
(not classified), a flexible insulating casing consisting of 100 mm
of foam covered with a flexible PVC envelope.