© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Basic Installation/Operation
70421501 (EN)
22
170 Pound Tumble Dryers
Figure 4
TMB2024N
NOTE: Refer to
for sizing of steam lines. Piping must also be sized accordingly for length of runs and number
of elbows.
1
Risers 305 mm (12 in.)
6
457 mm (18 in.) Drop
2
Shut-Off Valve
7
Steam Bonnet
3
Check Valve
8
Solenoid Valve (Supplied with machine)
4
Vacuum Breaker (optional)
9
Union
5
Condensate Return Line from Supply Line
10
Trap with Built-In Strainer
TMB2024N
SUPPLY
2
1
9
3
RETURN
2
3
7
10
4
5
8
6
Model
Steam Pressure
bar (PSI)
Minimum Pipe Diameter
Steam Trap Size*
(Pounds Condensate/Hour)
170S
7.5 - 8.6 (110-125)
1 in. NPT
517
4.1 - 7.5 (60-110)
1-1/4 in. NPT
517
2.4 - 4.1 (35-60)
1-1/2 in. NPT
517
* Based on maximum PSI.
Table 4
www.groupdynamics-laundry.com