Basic Installation/Operation
13
70421501 (EN)
Position and Level the Tumble Dryer
TMB2020N
NOTE: Shaded areas indicate adjacent structure.
1
13 mm (0.5 in.) recommended between machines for removal or installation.
2
Allow 51-102 mm (2-4 in.) opening at top of machine to aid in removal or installation. A removable trim piece
may be used to conceal the opening; zero clearance allowed for trim.
3
102 mm (4 in.) maximum header thickness
4
Minimum clearance permitted for remainder: Gas 102 mm (4 in.), Steam 305 mm (12 in.)
5
Guard
6
Provision for Make-Up Air
7
610 mm (24 in.) minimum, 914 mm (36 in.) recommended for maintenance purposes
8
6 mm (0.25 in.) recommended for removal or installation purposes, zero clearance allowed
Figure 1
TMB2020N
4
1
5
6
7
3
WARNING
To reduce the risk of severe injury, clearance of tumble dryer cabinet from combustible
construction must conform to the minimum clearances.
W056R1
8
2
www.groupdynamics-laundry.com