background image

MSFI 

-

 F801306

 

12

 

 

Pump Type

 

Recommended Lubricants

 

Oils SAE 

80/90

 

NLGI# 000

 

NLGI# 00

 

NLGI# 0

 

NLGI# 1

 

NLGI# 2

 

MSFi

 

-

40°F (

-

40°C)

 

-

29°F (

-

34°C)

 

-

8°C (

-

23°C)

 

2°F (

-

17°C)

 

9°F (

-

13°C)

 

14°F (

-

10°C)

 

Upper Temp Limit

 

+40°C (+104°F) for all pumps

 

Recommended Lubricants

 

Recommended Lubricants

 

The AX Pump has been developed specifically to run with NLGI Grade 000, 1,  2 grease and FG3,0 fluid grease. Oils to a minimum viscosity 
of SAE80 are also acceptable. 

Do not use heavy, tackified greases, greases containing bentone/bentonite or greases containing molyb-

denum and/or graphite.

 

NOTE: 

To ensure proper operation of the lubrication system, only fill with clean lubricant that has been in a sealed container and correctly 

stored. Failure to use clean lubricant can result in premature system or bearing failures.

 

Recommended Lubricants Operational Temperatures

 

 

(Based on maximum lubricant distribution line length of 35ft/10.7m*)

 

*Maximum line length dependent upon environmental temperature and lubricant being used.

 

110/220 VAC Pump Output Combinations*

 

Pump 

Element

 

Timer Setting (Delay Cycle)

 

#1 

-

 

6min

 

#2 

-

 

15min

 

#3 

-

 

30min

 

#4 

-

 

60min

 

Red

 

0.05

 

0.03

 

0.018

 

0.01

 

Green

 

0.075

 

0.044

 

0.025

 

0.014

 

Yellow

 

0.125

 

0.073

 

0.042

 

0.023

 

Blue

 

0.200

 

0.116

 

0.067

 

0.036

 

Grey

 

0.300

 

0.174

 

0.100

 

0.055

 

Black

 

0.500

 

0.290

 

0.167

 

0.091

 

Output shown in cc

s (grams) per hour.

 

All AX pumps come standard with blue pumping elements 

set at the #3 setting. All other pumping elements sold 

separately. 

 

12/24 VDC Pump Output Combinations*

 

Pump 

Element

 

Timer Setting (Delay Cycle)

 

#0 

-

 

1.8rpm

 

#1 

-

 

6min

 

#2 

-

 

9min

 

#3 

-

 

12min

 

#4 

-

 

27min

 

#5 

-

 

42min

 

#6 

-

 

57min

 

Red

 

0.240

 

0.067

 

0.050

 

0.040

 

0.020

 

0.013

 

0.010

 

Green

 

0.360

 

0.101

 

0.075

 

0.060

 

0.030

 

0.020

 

0.015

 

Yellow

 

0.600

 

0.168

 

0.125

 

0.100

 

0.050

 

0.033

 

0.025

 

Blue

 

0.960

 

0.268

 

0.200

 

0.160

 

0.080

 

0.052

 

0.040

 

Grey

 

1.440

 

0.402

 

0.300

 

0.240

 

0.120

 

0.078

 

0.060

 

Black

 

2.400

 

0.670

 

0.500

 

0.400

 

0.200

 

0.130

 

0.100

 

Output shown in cc

s (grams) per hour.

 

All AC pumps come standard with blue pumping elements set at the #4 setting.

 

All other pumping elements sold separately. 

 

 

System Output Combinations

 

MultiLine AXL Kits incorporate modular functionality which allows the user to increase or decrease system output by changing pumping 
elements, adjusting timer settings or both. Combinations shown below.

 

AC Pumps

 

The preferred method to increase or decrease system output is through the use of the externally programmable PCB (see pages 7

-

8).

 

Alternatively, the blue pumping elements can be replaced with pumping elements of varying outputs (see page 5). 

 

AX Pumps

 

The preferred method to increase or decrease system output is by replacing the blue pumping elements with pumping elements of

 

varying outputs (see page 5). Alternatively, the timer setting can be adjusted by accessing the switches on the PCB (see pages 9

-

10).

 

 

*All outputs above are approximate. The type of lubricant, line length, and environmental conditions (temperature) may affect system output.

 

Summary of Contents for MSFi

Page 1: ...e the accuracy of the information contained in this catalog but no liability is accepted for errors omissions or for any other reason Applicable Pumps AC15XXL 2 A AC25XXL 2 A AX13XXL A AX23XXL A Appli...

Page 2: ...cludes but is not limited to Protective eyewear Respirators protective clothing and gloves as recommended by the Lubricant manufacturer PLASTIC PART CLEANING SOLVENT HAZARD Many solvents can damage pl...

Page 3: ...ty Directive 2006 42 EC Machinery Directive 2011 65 EC Restriction of Certain Hazardous Substances Has been designed and manufactured to the following specifications BS EN 61000 6 2 2005 BS EN 61000 6...

Page 4: ...ancillary equipment Using the pump mounted adhesive template part number 31867 900 supplied position and drill the bracket holes mounting positions and bracket clearances detailed as per the above ima...

Page 5: ...ng from the furthest point from the pump feed the lubrication lines through the machine following existing machine services where possible Ensure that the lubrication lines are positioned to fit the b...

Page 6: ...e images 3 and 4 below A choice of fittings are available to suit all requirements see page 16 Accessories 1 2 3 4 The MSFi systems are suitable for use with most bearing types Brushes are available f...

Page 7: ...h red or be continuously lit red depending on the current programming setting The red illumination or flashing of the LED indicates that the pump is in the programming mode and is showing the current...

Page 8: ...is a continuous power supply to the circuit and pump The indicator light will flash green when the motor is in operation and is lit red when in the programming mode Pressing the manual override butto...

Page 9: ...ake sure to retain the O ring 5 Access PCB D and adjust dip switch as required see PCB 83344 426 image at the bottom of this page for the location of the dip switch 6 Re assemble ensuring the drive ad...

Page 10: ...switched on and after the allotted dwell time of the already pro grammed pump has elapsed The pump will run for 6 minutes and dwell for the allotted time as programmed 6 minutes dwell if 6 minute pro...

Page 11: ...e A VDC Pump R1 calibrated with 2 Red P E O1 4 Yellow P E O3 6 Grey P E O5 programmed for a 15 minute cycle time 2x0 01 4x0 025 6x0 06 0 48cc 1250cc 0 48cc 2604 16 Revs 2604 16 x 15 39017 4 minutes un...

Page 12: ...pumping elements set at the 3 setting All other pumping elements sold separately 12 24 VDC Pump Output Combinations Pump Element Timer Setting Delay Cycle 0 1 8rpm 1 6min 2 9min 3 12min 4 27min 5 42m...

Page 13: ...ll variants come with externally programmable blink code timer continuous 6 9 12 27 42 and 57min delay options All variants come with 5ft pump wire male AMP Superseal and a matching 30ft wire harness...

Page 14: ...EMBLY PADDLE ASSEMBLY WITH DRIVE ADAPTER 2L 1 7 32814 624 32814 763 32814 764 CAMSHAFT ASSEMBLY 12 PORT CAMSHAFT ASSEMBLY 24 PORT CAMSHAFT ASSEMBLY 36 PORT 1 8 32478 312 32478 328 32478 336 MANIFOLD R...

Page 15: ...MSFI F801306 15 Note Wiring connection may differ from that shown 1 3 4 5 6b 7 8 9 10 12 2 11 6a 6c Exploded View...

Page 16: ...152057 164 4mm Nylon Tubing Un Primed 50m 164ft A411 Oil Brush L2 4 x W1 2 G1 4 MSF T 4N50G 4mm Nylon Tubing Primed Grease 15m 50ft A412 Oil Brush L3 9 x W1 2 G1 4 152823 164 4mm Nylon Tubing Primed...

Page 17: ...ork a Refer to Problem A b Dwell time is too long or b Reduce the system dwell time c Lubrication quantity is too little c Change the pumping element with an increased output d System is blocked d Ref...

Page 18: ...Solution A Pump does not work a No input power a Check for power to the pump and controller b Fuse is blown b Check in line fuse replace if necessary c Loose broken wire connection inside the pump c C...

Page 19: ...____________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________...

Page 20: ......

Reviews: