17
OM-TDH
OM-TDH
17
f.
Replace the stainless knob shroud and
align holes.
g.
Start both screws but do not tighten.
h.
Put Teflon tape on the screw threads of the
thermostat bulb and insert into bottom of
kettle. Tighten hand tight plus one turn.
i.
Install bottom cover on skirt. Tighten
screws and gasket to 10-12 in-lb torque.
j.
Turn the kettle upright and tighten the two
thermostat mounting screws.
k.
Install knob by pushing straight on shaft.
l.
If the knob appears loose, remove and
gently spread the two prongs of the shaft
and reinstall knob.
m. Check water level.
n.
Remove air from jacket.
19.
Removal of water level probe
a.
Tilt kettle 90° and remove bottom cover.
b.
Remove yellow wire from probe.
c.
Unscrew probe from kettle jacket.
20.
Installation of water probe
a.
Apply Teflon tape to probe threads.
b.
Screw probe into kettle jacket and torque to
150 in-lbs.
c.
Attach yellow wire to probe.
d.
Reinstall bottom cover.
e.
Check water level.
f.
Remove air from jacket.
21.
Removal of pressure switch
a.
Tilt kettle a full 90°.
b.
Remove bottom cover.
c.
Unplug red and white wires from switch.
d.
Using a 9/16 open end wrench, carefully
unscrew the pressure switch from the 90°
elbow.
22.
Installation of pressure switch
a.
Hand start the pressure switch into the 90°
elbow.
b.
Using a 9/16 wrench, tighten the switch to
90 in-lbs.
c.
Reattach the red and white wires to the
switch.
d.
Reinstall bottom cover.
e.
Check water level.
f.
Remove air from jacket.
Thermostat and Gasket Installation Detail