background image

5

1. installation

Minimum  Clearances:  SmartSteam  Boilerless 

Steamer  requires  the  following  minimum 

clearances to any surface, combustible or non-

combustible.

 

Right Side 

2 inches

 

Left Side 

2 inches

 

Rear   

6 inches

Steam Free Zone: The SmartSteam Boilerless 

Steamer  can  be  damaged  by  steam  from 

external  sources. 

Do  not  install

  the  steamer 

over a steam venting drain. Ensure that steam is 

not present in an area bounded by the footprint 

of the steamer and a circle 18 inches in radius 

about the right rear corner of the steamer (see 

figure below).

Install  and  operate  the  gas  appliance  in  a  well 

ventilated  area.  Adequate  air  must  be  supplied  to 

replenish  the  air  used  for  combustion.  Installation 

must  conform  with  local  codes  and/or  with  the 

Naitonal  Fuel  Gas  Code,  ANSI  Z.1/NFPA-5 

(latest  edition)  or  the  National  Gas  and  Propane 

Code CSA B19.1 as applicable.

Any item which might obstruct or restrict the flow of 

air for combustion and ventilation must be removed. 

Do  not  obstruct  the  flue  cover  or  rear  vents  after 

installation.

tHe area DirectlY arounD tHe appliance 

must  be  cleareD  of  all  combustible 

material.  failure  to  folloW  tHese 

instructions  can  cause  boDilY  inJurY 

anD/or propertY Damage.

The  steamer  must  be 

disconnected 

from  the  gas 

supply  system  during  any  pressure  testing  of  that 

system which has test pressures 

in exxcess of 

1

/

 

PSI (.5 kPa).

2.  electrical supply connection

 

Provide  115  VAC,  60  HZ,  1  PH,  15  AMP 

 

service. Bring wire in through hole in the lower 

 

left back panel. Each cavity requires a separate 

 

cord  for  connections.  Local  codes  and/or  the 

 

National Electrical Code should be observed in 

 

accordance  with  ANSI/NFPA  70. 

an 

 

electrical  grounD  is  reQuireD.

 

 

The  wiring  diagram  is  located  in  the  service 

 

compartment and in this manual. Maximum load 

 

is  

1

/

    AMPs.  In  Canada,  provide  electrical 

 

service  in  accordance  with  the  Canadian 

 

Electrical Code, CSA C. Part 1 and/or local 

 

codes.

3.  gas supply connection

 

Connection  to  the  gas  supply  shall  be  in 

 

accordance with the chart below.

om-ssb-3g/5g/10gf

installation and startup

Warning

     

tHe  unit  must  be  installeD  bY  personnel  WHo are  QualifieD  to  WorK  WitH    gas, 

electricitY    anD  plumbing.  improper  installation  can  cause  inJurY  to  personnel 

anD/or  Damage  to  tHe  eQuipment.  tHe  unit  must  be  installeD  in  accorDance  WitH 

applicable coDes. tHe unit must be installeD bY a licenseD plumber or gas fitter 

WHen installeD WitHin tHe commonWealtH of massacHusetts.

caution

  Do not install tHe unit WitH tHe rear Vents blocKeD or WitHin 2 incHes of a Heat source 

  sucH as a braising pan, Deep fat frYer, cHarbroiler or Kettle.

  

to aVoiD Drainage problems, leVel tHe unit front to bacK, or pitcHeD sligHtlY to 

  tHe rear.

npt pipe size required

1

/

1

/

1

/

1

/

/

/

ssb-steamer

SSB-G

()SSB-G

SSB-5G

()SSB-5G

SSB-10G

()SSB-10G

18 -inch

radius

SMArTSTEAM

(top view)

57 mm

Summary of Contents for SSB-10GF

Page 1: ...TRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AT A MINIMUM TURN OFF GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED S...

Page 2: ...LEANING THE OUTSIDE OF THE STEAMER DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNI...

Page 3: ...ce 13 troubleshooting 13 service log 15 warranty protection 17 References underwriters laboratories inc national fire protection association 333 Pfingsten Road 60 Batterymarch Park Northbrook Illinois...

Page 4: ...back when cut Carefully cut the straps and detach the sides of the carton from the skid Pull the carton up off the unit Be careful to avoid personal injury or equipment damage from staples which might...

Page 5: ...s test pressures in exxcess of 1 2 PSI 3 45 kPa 2 Electrical Supply Connection Provide 115 VAC 60 HZ 1 PH 15 AMP service Bring wire in through hole in the lower left back panel Each cavity requires a...

Page 6: ...gcodeoftheBuildingOfficials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the Food and Drug Administration FDA NOTE Local code may also require check valves...

Page 7: ...reachsteamertobestacked Each steamer unit must have it s own branch circuit protection C Gas Connection A single gas connection is required for both steamers Gas supply must be adequate under all cond...

Page 8: ...ol panel note For normal day to day operation the rocker switch may be left in the ON position Use the upper control panel ON OFF button to turn unit ON and OFF 6 When the steam generating reservoir h...

Page 9: ...nerator cools and the HI TEMP indicator light goes out The TIMING indicator light stays on when the timer is running The Lower White SERVICE indicator light shows when the control cooling fan may not...

Page 10: ...you must control steaming time warning when you open the door stay away from the steam coming out of the unit steam can cause burns 5 Open the door Remove the pans from the steamer using hot pads or o...

Page 11: ...Cleaning Daily cleaning must be done in order to enhance the performance and prolong the life of your SmartSteam Boilerless Steamer important do not use any metal material such as metal sponges or me...

Page 12: ...n float probes if food residue or loose scale is present A thin layer of tightly bound scale is normal and will not affect steamer performance If scale is excessive then refer to deliming instructions...

Page 13: ...If an item on the check list is marked with x it means that the work should be done by a Groen Authorized Service Agent symptom who what to check 1 Blinking Service Light User a Clean probes in unit C...

Page 14: ...or pops open User a Ensure drain and vent are not plugged No more than two units should be attached to a single drain line b Check door pin adjustment per above c Call for service technician 10 HI TEM...

Page 15: ...__________________ Purchased From ______________________ Serial No ___________________________ Location _____________________________ Date Purchased_______________________ Date Installed______________...

Page 16: ...16 om ssb 3g 5g 10gf NOTES...

Page 17: ...and installed a Groen PureSteem Water Treatment System for use in connection with such Groen Convection Combo Steamer Oven HyPerSteam Convection Steamer or HyPlus Pressureless Steamer on or before te...

Page 18: ...ver defects caused by improper installation abuse careless operation or improper maintenance of Groen Equipment This warranty does not cover damage to Groen Equipment caused by poor water quality or i...

Page 19: ...er Ovens HyPerSteam Convection Steamers and HyPlus Pressureless Steamers or b electronic relay and control boards contained in Groen Convection Combo Steamer Ovens or c Groen SmartSteam Boilerless Ste...

Page 20: ...om ssb 3G 5G 10Gf Part Number 145144 Rev D Revised 09 05 1055 Mendell Davis Drive Jackson MS 39272 Telephone 601 372 3903 Fax 601 373 9587 www groen com...

Reviews: