background image

9

a. controls

Operator controls are on the front right of the unit.

The  SmartSteam  Boilerless  Steamer  control  panel 

has the following touch pads and indicator lights:

 

  The ON/OFF touch pad gets the SmartSteam 

 

  Boilerless  Steamer  ready  for  use  and  also

 

  shuts it OFF.

 

  The  rEADY  indicator  light  shows  that  the 

 

  steam  generating  reservoir  is  at  standby 

 

  temperature and the cavity is hot enough to 

 

  begin steaming.

 

  The Upper/red SErVICE indicator light and 

 

  Door/Lid light indicate the water level probes 

 

  have  stopped  working  and  need  to  be 

 

  cleaned.

 

  The Door/Lid Indicator light illuminates when 

 

  the door is not properly closed.

 

  The HI TEMP indicator light comes on when 

 

  the unit is too hot.

 

 

The  unit  will  automatically  shut  off 

and

 

  cannot  be  turned  on  again  until  the 

 

  steam  generator  cools  and  the  HI  TEMP 

 

  indicator light goes out.

 

  The  TIMING  indicator  light  stays  on  when   

 

  the timer is running.

 

  The  Lower/White  SErVICE  indicator  light 

 

  shows when the control cooling fan may not 

 

  be functioning properly. The light may come 

 

  on  for  several  minutes  during  normal 

 

  operation.  If  it  stays  on  for  more  than  0 

 

  minutes,  call  for  service.  It  is  okay  to  use 

 

  steamer until service  arrives, but continued 

 

  use  for  prolonged  periods  could  result  in 

 

  component  damage  due  to  excessive 

 

  temperatures.

 

  The  hour  meter  records  the  cumulative 

 

  hours the steamer has been used. refer to 

 

  warranty statement.

om-ssb-3g/5g/10gf

operation

Warning

  anY potential user of tHe eQuipment must be traineD in safe anD correct operating

  proceDures.

P/N 149398 REV B

Dial off position

oN Light

TIMING Light

REd SERVICE Light

Hi temp

indicator

cooling fan

Indicator Light

doNE Light

timeD

Cooking dial

REAdY Light

Door open

Light

control

power

on/off

Touch Pad

PoWER Light

Hour meter

Summary of Contents for SSB-10GF

Page 1: ...TRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AT A MINIMUM TURN OFF GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED S...

Page 2: ...LEANING THE OUTSIDE OF THE STEAMER DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNI...

Page 3: ...ce 13 troubleshooting 13 service log 15 warranty protection 17 References underwriters laboratories inc national fire protection association 333 Pfingsten Road 60 Batterymarch Park Northbrook Illinois...

Page 4: ...back when cut Carefully cut the straps and detach the sides of the carton from the skid Pull the carton up off the unit Be careful to avoid personal injury or equipment damage from staples which might...

Page 5: ...s test pressures in exxcess of 1 2 PSI 3 45 kPa 2 Electrical Supply Connection Provide 115 VAC 60 HZ 1 PH 15 AMP service Bring wire in through hole in the lower left back panel Each cavity requires a...

Page 6: ...gcodeoftheBuildingOfficials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the Food and Drug Administration FDA NOTE Local code may also require check valves...

Page 7: ...reachsteamertobestacked Each steamer unit must have it s own branch circuit protection C Gas Connection A single gas connection is required for both steamers Gas supply must be adequate under all cond...

Page 8: ...ol panel note For normal day to day operation the rocker switch may be left in the ON position Use the upper control panel ON OFF button to turn unit ON and OFF 6 When the steam generating reservoir h...

Page 9: ...nerator cools and the HI TEMP indicator light goes out The TIMING indicator light stays on when the timer is running The Lower White SERVICE indicator light shows when the control cooling fan may not...

Page 10: ...you must control steaming time warning when you open the door stay away from the steam coming out of the unit steam can cause burns 5 Open the door Remove the pans from the steamer using hot pads or o...

Page 11: ...Cleaning Daily cleaning must be done in order to enhance the performance and prolong the life of your SmartSteam Boilerless Steamer important do not use any metal material such as metal sponges or me...

Page 12: ...n float probes if food residue or loose scale is present A thin layer of tightly bound scale is normal and will not affect steamer performance If scale is excessive then refer to deliming instructions...

Page 13: ...If an item on the check list is marked with x it means that the work should be done by a Groen Authorized Service Agent symptom who what to check 1 Blinking Service Light User a Clean probes in unit C...

Page 14: ...or pops open User a Ensure drain and vent are not plugged No more than two units should be attached to a single drain line b Check door pin adjustment per above c Call for service technician 10 HI TEM...

Page 15: ...__________________ Purchased From ______________________ Serial No ___________________________ Location _____________________________ Date Purchased_______________________ Date Installed______________...

Page 16: ...16 om ssb 3g 5g 10gf NOTES...

Page 17: ...and installed a Groen PureSteem Water Treatment System for use in connection with such Groen Convection Combo Steamer Oven HyPerSteam Convection Steamer or HyPlus Pressureless Steamer on or before te...

Page 18: ...ver defects caused by improper installation abuse careless operation or improper maintenance of Groen Equipment This warranty does not cover damage to Groen Equipment caused by poor water quality or i...

Page 19: ...er Ovens HyPerSteam Convection Steamers and HyPlus Pressureless Steamers or b electronic relay and control boards contained in Groen Convection Combo Steamer Ovens or c Groen SmartSteam Boilerless Ste...

Page 20: ...om ssb 3G 5G 10Gf Part Number 145144 Rev D Revised 09 05 1055 Mendell Davis Drive Jackson MS 39272 Telephone 601 372 3903 Fax 601 373 9587 www groen com...

Reviews: