OM/SM-HY-3E & HY-5E(CE)
23
Service Procedures
[FOR PROFESSIONAL TECHNICAL SERVICE PERSONNEL ONLY]
General Information
:
The following procedures are based upon having
access to the steamer on all four sides. If the
steamer is installed between other appliances and
there is not enough room on the sides for access,
the steamer must then be pulled out from its position
to gain proper access.
Care should be taken in moving the steamer so as
not to stress or pull on the electrical or water
connections.
WARNING
THERE IS HIGH VOLTAGE INSIDE CONTROL
COMPARTMENTS. DISCONNECT UNIT
BEFORE SERVICING. FAILURE TO DO SO
CAN RESULT IN SERIOUS INJURY OR DEATH.
NOTICE
: Refer to the Electrical Schematic Diagram
and the Interconnect Diagram to identify and/or
confirm terminal designations or wire colors.
A. Side Panel - Removal
P/N 123134 - Right Panel
P/N 123135 - Left Panel
1.
With a flat blade screw
driver remove two 10-32
screws on the lower
edge and one on the top
edge of the panel. The
panel is retained to the
steamer by spring-like
clips at the rear edge.
2.
Once the screws are
removed SLIDE the
panel towards the front.
Do not attempt to PRY
the panel. Once the
panel is free of the rear
clips, it may be lifted off
the top track.
Assembly Tip
. When replacing the panel, press the
rear edge inward so that all three clips will be
retained by the back flange. Make sure that the holes
in the panel are in alignment with the tapped holes in
the steamer so that the replacement of the three
screws will be easy and not damaging.
B. Top Panel - Removal
P/N 096777
In order to replace the water drain valve, the
condensate spray nozzle, alternate door switch
location, or the steam generator, the top and left side
of the steamer external cabinet must be removed.
The following procedures are to be used:
1.
First, remove the side panel as described in
Section A.
2.
Remove the retaining bracket which
prevents the top from sliding forward.
3.
The top and side assembly may then be slid
forward and once clear of the retaining clips,
may be lifted off.
Assembly Tip.
In replacing the top panel assembly,
make sure that the retaining clip is replaced and
screwed down tight.
C.
Support Table (Optional)
P/N 100913
1.
The steamer is
supported on a
stainless steel
table. The
steamer is
attached to the
table by four 1/2"
bolts fastened
from below.
2.
To remove the
steamer from
table, disconnect
electric, water
and drain lines
from the
steamer. Then
remove the four
bolts.
3.
Each leg is
provided with a screw type support post.
These may be extended or retracted by
turning them with a wrench or ChannelLock.
Make sure that all four legs are in tight