SM-GSSP BOILERLESS STEAMER

circuit power relay or gas valve and maintains the ready conditions by cycling 
the elements 18 seconds ON, 6 minutes OFF.
If the MANUAL mode is on, the heater control continuously turns on heat to 
produce steam.
If HOLD mode is on, the HOLD and READY thermostats operate the control the 
heat on the following conditions:

Scenario #1

1.   When “HOLD” button is pressed, if HOLD and READY thermostats are 

closed then heat will turn on.

2.   Heat will remain on until HOLD and READY thermostat opens. 
3.   When READY thermostat opens, heat turns off.
4.   Heat will remain off until READY thermostat closes then heat ON/OFF 

cycle rate will initiate.

5.   Heat cycle will continue until HOLD “X” is pressed to exit or the unit is 

turned off.

6.   If the HOLD thermostat closes due to drop in temperature, and the 

READY thermostat is still closed, then the heat turns on and sequence 
returns to step 2.

Scenario #2

1.   When “HOLD” button is pressed, if HOLD thermostat is open and READY 

thermostat is closed then heat will turn on.

2.   Heat will remain on until READY thermostat opens. 
3.   When READY thermostat opens, heat turns off.
4.   Heat will remain off until READY thermostat closes then heat ON/OFF 

cycle rate will initiate.

5.   Heat cycle will continue until HOLD “X” is pressed to exit or the unit is 

turned off.

6.   If the HOLD thermostat closes due to drop in temperature, and the 

READY thermostat is still closed, then the heat turns on and sequence 
returns to step 2. 

Scenario #3

1.   When “HOLD” button is pressed or “Timed Cook” mode expires, if HOLD 

and READY thermostats are open, then heat will turn off.

2.   Heat will remain off until READY thermostat closes. 
3.   Heat will remain off until READY thermostat closes then heat ON/OFF 

cycle rate will initiate.

4.   Heat cycle will continue until HOLD “X” is pressed to exit or the unit is 

turned off.

5.   If the HOLD thermostat closes due to drop in temperature, and the 

READY thermostat is still closed, then the heat turns on and sequence 
returns to step 2.

A High-Limit thermostat is provided as a safety device on each steam reservoir 
to monitor the internal temperature of the steam reservoir. This temperature is 
set for 280ºF and will shut down the steamer if there is very little or no water and 
the steamer cavity starts to overheat.

DRAINING WATER FROM THE STEAM RESERVOIR

When water or steam is drained from the reservoir, it passes through a water 
spray in the drain box controlled by a water solenoid valve to condense the 
steam before it exits the steamer drain box into the drain line.
A solenoid drain valve is connected to each steam reservoir. This valve is 
normally open, permitting water from the steam reservoir to drain out. When the 
unit is turned on, the steam generator drain valve closes and the steam reservoir 
starts to fill/drain, and the sequence runs until water reaches the proper level 
for cooking operation.

When the unit is turned off, the solenoid valve opens and drains the water from 
the steam reservoir. When water is drained from the steam reservoir, it passes 
through the drain box and then into the drain line.
When the unit is turned off by the ON/OFF push button, the steamer will fill to the 
high probe, drain, refill and drain. This is to remove the heat from the reservoir 
for cleaning and reduce any possible cavity warping.
*If hot water is existing, the drain fan thermal switch could close and energize 
circuit giving error code 19.

LOW WATER LEVEL DETECTION 

Because prolonged operation with less than the required amount of water in the 
steam reservoir could present a dangerous situation, the control takes action to 
prevent the situation.
If the low probe is satisfied, the heat turns on and continues operation. If the low 
probe is not satisfied, the control begins to operate unit on the HIGH water level 
probe for a period up to a 8 hours maximum.   

INSTALLING, CLEANING & TESTING

WARNING:  THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO 

WORK WITH GAS, ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION 

CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE QUIPMENT. 

THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES.

CAUTION:   DO NOT INSTALL THE UNIT WITH THE REAR VENTS BLOCKED, OR WITHIN 2 

INCHES OF A HEAT SOURCE SUCH AS A BRAISING PAN, DEEP FAT FRYER, 

CHARBROILER OR KETTLE. TO AVOID DRAINAGE PROBLEMS, LEVEL THE 

UNIT FRONT TO BACK, AND PITCH IT SLIGHTLY TO THE FRONT.

WARNING:   TO AVOID DAMAGE OR PERSONAL INJURY, FOLLOW THE WIRING DIAGRAM 

EXACTLY WHEN CONNECTING THE UNIT.

CAUTION:   EACH UNIT MUST HAVE A SEPARATE GROUND WIRE FOR SAFE OPERATION.

ELECTRIC MODEL INSTALLATION

ELECTRICAL SUPPLY CONNECTION

1.  Panel Removal – Right Side: Open the wiring and control panel by removing 

screws from the right side panel. Slide the panel forward and set it aside.

2.  Supply Voltage: The unit must be operated at the rated name plate voltage. 

The name plate can be found on the right side panel.

3.  Phase Selection: Refer to steamer wiring diagram (pages 15-16) and 

element wiring (pages 8-10).

4.  Terminal Block: The terminal block for incoming power is located at the back 

of the control compartment, the ground terminal is located in the wiring 
compartment near the terminal block.

5.  Supply Wire: The equipment grounding wire must comply with the National 

Electrical Code (NEC) requirements. The wiring diagram on the inside of 
the unit’s right side cover gives directions for the proper connection of the 
terminal block to the supply power. The proper wire must be used or the unit 
will not meet Underwriters Laboratories and NEC requirements. The electric 
hole is sized for a 1” conduit fitting on the GSSP-BL-3E and GSSP-BL-5E. 
The electric hole is sized for a 1-1/4” conduit fitting on the GSSP-BL-10E.

6.  Branch Circuit Protection: Each SmartSteam Pro Boilerless Steamer, 

including individual units of stacked models, should have its own branch 
circuit protection and ground wire. Current and power demands for each 
unit are as shown below.

Summary of Contents for GSSP-BL-10G

Page 1: ...his document is Confidential and shall not be disclosed to any third party without the express written consent of Unified Brands Information contained in this document is known to be current and accur...

Page 2: ...dous situation exists and could result in serious injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance When you open the st...

Page 3: ...NY POTENTIAL USER OF THE EQUIPMENT MUST BE TRAINED IN SAFE AND CORRECT OPERATIONG PROCEDURES WARNING WHEN YOU OPEN THE DOOR STAY AWAY FROM THE STEAM COMING OUT OF THE UNIT THE STEAM CAN CAUSE BURNS WA...

Page 4: ...een displayed no cooking mode selected the heater control cycles the heating OPERATING PROCEDURE 1 Press the ON OFF push button The screen will display a self diagnostic screen with progress bar The d...

Page 5: ...ing operation When the unit is turned off the solenoid valve opens and drains the water from the steam reservoir When water is drained from the steam reservoir it passes through the drain box and then...

Page 6: ...t least 4 5 W C maximum 14 W C for natural gas or 12 W C maximum 14 W C for LP gas In Canada the installation must conform to the Canadian Gas Code CAN 1 B149 Installation Codes for Gas Burning Applia...

Page 7: ...RE CLEANING THE OUTSIDE OF THE STEAMER KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELEVTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT AVOID CONTACT WITH ANY CLEANSER DELIMI...

Page 8: ...egar Commercial vinegar 5 to 7 strength has been used successfully by a number of SmartSteam users as a descaler Follow the same instructions as when using delimer descaler CLEANING STEPS If the Delim...

Page 9: ...9 SM GSSP BOILERLESS STEAMER GSSP BL 5E 208 240V 1 PHASE GSSP BL 5E 208 240V 3 PHASE GSSP BL 5E 480V 3 PHASE USING 277V ELEMENTS IN WYE CONFIG GSSP BL 10E 208 240V 1 PHASE GSSP BL 10E 208 240V 3 PHASE...

Page 10: ...rm the value for 24 VAC at the secondary of the control transformer Values should be between 22 and 26 VAC and solid red LED on I O board Record value on sheet 8 11 Check Board Temp value and confirm...

Page 11: ...ithin 10 rating on data plate 13 Low Voltage Fatal Transformer output voltage is below 19V Ensure incoming voltage supply is within 10 rating on data plate Error Error Name Trouble Condition Error Typ...

Page 12: ...Make sure hi limit and drain thermostats are closed AMPERAGE RESISTANCE CHART Model Voltage Phase Amperage Resistance GSSP BL 5E 208 Three Phase 34 6 1 GSSP BL 5E 240 Three Phase 29 8 3 GSSP BL 5E 480...

Page 13: ...13 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL 3E 5E 10E 888 994 7636...

Page 14: ...14 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL 3G 5G 10G 888 994 7636...

Page 15: ...15 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Page 16: ...16 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Page 17: ...17 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Page 18: ...18 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Page 19: ...19 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Page 20: ...20 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Page 21: ...21 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Page 22: ...22 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Page 23: ...four studs on the high voltage panel 2 Install 6 32 lock nuts onto the studs and tighten in place using a 5 16 socket 3 Insert all jacks in the same connector locations as per removal Press firmly to...

Page 24: ...tch inside the front panel of the steamer on each side of the cavity It is pre wired in parallel so no wiring change is necessary when the door is reversed 17 Close steamer door and operate steamer If...

Page 25: ...three exterior screws 3 Remove the side access panel by removing the two 10x32 nuts 4 Unplug the HIS and flame sensor 5 Remove the 5 14 screws on the holding plate near the ignition tube and on the b...

Page 26: ...44110 SCREW 8 X 1 2 HEX HD SLOT MACHINE SELF 410SS 11 11 071256 NUT HEXHEAD KEPS 10 32 2 10 145088 WELDMENT LEFT COMB CHAMBER ACCESS 1 9 143986 WELDMENT FLUE EXTENSION BRACKET BOTTOM 1 8 143976 BURNER...

Page 27: ...TEAMER Parts List GSSP BL 3G 5G 10G BASE CAVITY ASSEMBLY 178124 9 5 7 4 7 INSULATION HIDDEN 18 SECTION A A INSUALTION HIDDEN 16 15 14 13 12 13 17 8 1 10 17 A A B BOTH SIDES 2 6 11 8 3 8 17 DETAIL B SC...

Page 28: ...T LEFT COMB CHAMBER ACCESS 1 9 145257 WELDMENT HORIZONTAL FLUE SSB 10G 1 8 145074 BURNER ASSEMBLY INFRARED 1 7 178091 PLATE READY HOLD SENSOR GSSP 1 6 069784 8 32 KEPS NUT 2 5 178089 THERMOSTAT HOLD G...

Page 29: ...7 NT1101 NUT HEXSERRATEDZINC 1 4 20 4 8 004173 SCREW TRS HEAD 10 32 X 3 8 8 9 143870 INSULATION CAVITY BACK SSB 10 1 10 178857 INSULATION TOP SIDE GSSP 10 1 11 145624 PANEL REAR FIREWALL SSB 10 1 12...

Page 30: ...841 SCREW 4 40 X 1 4 HEX MS 4 12 178091 PLATE READY HOLD SENSOR GSSP 1 11 147285 THERMOSTAT READY SSB 3 5 1 10 178089 THERMOSTAT HOLD GSSP 1 9 069784 8 32 KEPS NUT 2 8 147693 SHEET GRAPHITE 3 7 141538...

Page 31: ...3 16 FA NUT0404 NUT TINNERMAN 10 11 15 142624 INSULATION BACK SSB 5 1 14 145160 PANEL BOTTOM LEFT FIREWALL SSB 5E 1 13 097015 SNAP BUSHING 1 3 8 INCH 1 12 149465 INSULATION TOP SIDE SSB 5 1 11 143655...

Page 32: ...REW 4 40 X 1 4 HEX MS 4 12 178091 PLATE READY HOLD SENSOR GSSP 1 11 147285 THERMOSTAT READY SSB 3 5 1 10 178089 THERMOSTAT HOLD GSSP 1 9 069784 8 32 KEPS NUT 2 8 147693 SHEET GRAPHITE 3 7 141538 PANEL...

Page 33: ...E SSB 3E G 1 13 071256 NUT HEXHEAD KEPS 10 32 4 12 145160 PANEL BOTTOM LEFT FIREWALL SSB 5E 1 11 143657 PANEL BOTTOM RIGHT FIREWALL SSB 3 5G 1 10 143889 PANEL REAR FIREWALL SSB 3G E 1 9 143893 INSULAT...

Page 34: ...34 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E ELECTRIC CAVITY ASSEMBLY 178201...

Page 35: ...35 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E BASE CAVITY ASSEMBLY 178200...

Page 36: ...36 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3G 5G 10G ELECTRICAL ASSEMBLY 178120...

Page 37: ...37 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3E 5E ELECTRICAL ASSEMBLY 178110...

Page 38: ...38 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E ELECTRICAL ASSEMBLY 178864...

Page 39: ...39 SM GSSP BOILERLESS STEAMER Parts List GSSP BL I O BOARD ASSEMBLY 178115...

Page 40: ...40 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3G 5G HIGH VOLTAGE ELECTRICAL PANEL 178128...

Page 41: ...41 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10G HIGH VOLTAGE ELECTRICAL PANEL 178963...

Page 42: ...42 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3E 5E HIGH VOLTAGE ELECTRICAL PANEL 178126...

Page 43: ...43 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3E 5E 480V HIGH VOLTAGE ELECTRICAL PANEL 178129...

Page 44: ...44 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E HIGH VOLTAGE ELECTRICAL PANEL 178127...

Page 45: ...45 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E 480V HIGH VOLTAGE ELECTRICAL PANEL 178962...

Page 46: ...46 SM GSSP BOILERLESS STEAMER Parts List GSSP BL CONTROL PANEL ASSEMBLY 178119...

Page 47: ...47 SM GSSP BOILERLESS STEAMER Parts List GSSP BL PLUMBING ASSEMBLY 178123...

Page 48: ...48 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3G 5G 10G GAS SUPPLY PIPING ASSEMBLY 178122...

Page 49: ...lue Date fields will require selection of the month day or year field before editing Door opening Always shuts down convection fan and heating circuit Water fill and drain allowed to proceed Circulati...

Page 50: ...and show first Delime screen Regardless of when during startup the button is pushed the unit will fill to High probe checking make break make transition If High probe is functioning a probe based del...

Page 51: ...il cleared by pressing the Okay button at the same time the shutdown clock at the top of the screen will start flashing until it reaches 0 00 12 00pm Timed Manual Hold SHUTDOWN H MM SS 12 00pm Timed M...

Page 52: ...will be differentiated from the main Timed Cook alarm The audible alarm will continue until silenced by tapping the flashing 0 00 Once acknowledged the timer notification will disappear If a second ti...

Page 53: ...open then heat will turn off Heat will remain off until READY thermostat closes Heat will remain off until READY thermostat closes then heat ON OFF cycle rate will initiate If the HOLD thermostat clos...

Page 54: ...e LONGER THAN COOK If a Pan timer is set for longer than an active cook time a pop up warning will appear when the timer is started Okay Returns to Timed Cook screen HOLD MODE TIMER SETTING Pop up occ...

Page 55: ...tings will be retained at power off and power disconnect SERVICE Service screen to include Startup Date grayed out after setting Unit Status Diagnostics Error Log Documents Operation Error Description...

Page 56: ...electing each individual data box Default value in the box should be MM DD YYYY Text in the boxes should be blue to indicate to the user that it can be changed DATE CONFIRMATION Accept Accepts the dat...

Page 57: ...g V 1 1 Firmware Update Data Retrieval Documents RTD Calibration Parameters Service Shutdown Needed Shutdown Needed Okay Cancel Unit needs to shutdown prior to entering Manual Diagnostics mode Restart...

Page 58: ...ters Code 12 00pm 0000 Enter Parameters Code 2 3 1 5 6 4 7 9 0 8 PARAMETERS CODE Parameters screen is protected by common unchangeable 4 digit password 7256 Each digit will be briefly displayed and th...

Page 59: ...ess Connect the USB drive before starting firmware update 12 00pm Firmware Update Start Start Firmware Update Start FIRMWARE UPDATE User shall connect a USB drive which shall have the executable files...

Page 60: ...during third fill drain cycle Delime complete screen is displayed Progress bar 25 at High probe M B M 50 after heating and end of second fill at High probe M B M 75 after drain and refill at High prob...

Page 61: ...atus of each component Okay Button Silences and removes alarm pop up until power is cycled If error reoccurs after power cycle pop up will reoccur Buttons and actions will vary with error type 1 30 45...

Page 62: ...fill to the High probe drain to Low probe past for XX minutes and refill to the High probe then drain cavity to empty If front ON OFF button is pressed or shutdown counter expires and High probe is fu...

Page 63: ...sate Tstat Open High Limit Thermostat Active Board Communication xxx mA Cooling Fan xxx mA Open Water Level High Open Water Level Overflow 12 00pm xxx mA Fill Valve xxx mA Drain Valve Condensate Valve...

Page 64: ...ware Update Data Retrieval Documents RTD Calibration Parameters Service 12 00pm Model Model Name Serial Number 638 903 518 9631 Manufacture Date 12 04 2020 Startup Date 04 20 2020 Firmware Version 1 0...

Page 65: ...65 SM GSSP BOILERLESS STEAMER Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...