57
SM-GSSP BOILERLESS STEAMER
DIAGNOSTICS
Diagnostics includes: Board Communication (Active (green font) / Lost (red font)),
Circulation Fan (ON/OFF), Fill Valve (ON/OFF Xxx mA), Drain Valve (On/ Off Xxx
mA), Condensate Valve (ON/OFF Xxx mA), Cooling Fan (ON/OFF Xxx mA), Water
Level Low (Open/Closed), Water Level High (Open/Closed), Water Level Overflow
(Open/Closed) (only with 3rd sensor), Door Switch (Open/ Closed), High Limit
Thermostat (state only, (Open/Closed), Ready tstat (state only, (Open/Closed),
Hold tstat (state only, (Open/Closed), Condensate tstat (state only, (Open/Closed),
Board Temp (XXX°C or XXX°F), Control Voltage (XXXV), Contactor (ON/OFF Xxx
mA). Items which are status only and cannot be activated should show the text
in black instead of blue including the mA values for items that can be toggled.
Screen update is real time. mA will be rounded to nearest 10 mA and below
32mA will show 0. Diagnostics cannot be activated in Delime, Data retrieval
or software update modes. In Service Mode (from Startup screen),selecting
Diagnostics will allow for manual operation of components. After exiting menu,
unit displays popup with Restart acknowledgment. If accepted, unit will restart
properly regardless of what was changed in Diagnostics mode. If not in Service
Mode, selecting Diagnostics will trigger a pop up stating that the unit will go
through a shutdown cycle first and ask for confirmation. If user cancels, screen
goes back to Service Menu. If users accepts, unit shows shutdown screen and
proceeds through Fill/ drain shutdown sequence. After shutdown, Diagnostics
screen is displayed. Upon exiting Service Menu via back button, unit displays
popup with Restart acknowledgment. Manual mode requires all safeties to
be active to prevent overheating, overfilling, etc. Consider only activating for
short period. Circulation Fan (ON/OFF), Fill Valve (On=30 secs, Off=Default),
Drain Valve (Open=Default, Closed=30 secs.), Condensate Valve (On=30 secs,
Off=Default), Cooling Fan (ON/OFF), Water Level Low (Open/Closed), Water Level
High (Open/ Closed), Water Level Overflow (Open/Closed) (only with 3rd sensor),
Door Switch (Open/Closed). Screen dimming is disabled.
12:00pm
Startup Date
Unit Status
Diagnostics
Error Log
V 1.1
Firmware
Update
Data Retrieval
Documents
RTD Calibration
Parameters
Service
Shutdown Needed
Shutdown Needed
Okay
Cancel
Unit needs to shutdown
prior to entering Manual
Diagnostics mode.
Restart
12:00pm
Startup Date
Unit Status
Diagnostics
Error Log
V 1.1
Firmware
Update
Data Retrieval
Documents
RTD Calibration
Parameters
Service
Restart Unit?
Restart
Cancel
Unit needs to restart
prior to resuming normal
operation.
SHUTDOWN NEEDED
Pop up occurs after selecting Diagnostics but prior to entering Diagnostic Mode.
Okay - Unit shuts down and displays Diagnostics menu.
Cancel - Unit returns to Service Menu.
12:00pm
Error Log
Probe Error - Low
02/04/2020 12:30pm
Low probe changed state
while hi probe on, Fatal
(B)=Before Error (A)=At Error
Fill Valve
Drain Valve
Condensate
Valve
Water Level
Low
Board Temp
Control
Voltage
Contactor
Circulation
Fan
Door Switch
Ready Tstat
Hold Tstat
Condensate
Tstat
High Limit
Thermostat
Board
Communication
Cooling Fan
Water Level
High
Water Level
Overflow
Active (B)
Active (A)
On (B)
On (A)
xxx mA
(B)
xxx mA
(A)
xxx mA
(B)
xxx mA
(A)
xxx mA
(B)
xxx mA
(A)
xxx mA
(B)
xxx mA
(A)
Open
(B)
Open
(A)
Open
(B)
Open
(A)
xxx°F
(B)
xxx°F
(A)
xxx mA
(B)
xxx mA
(A)
xxx V
(B)
xxx V
(A)
Open
(B)
Open
(A)
Open
(B)
Open
(A)
Open
(B)
Open
(A)
Open
(B)
Open
(A)
Closed
(B)
Closed
(A)
Open
(B)
Open
(A)
Error Log
12:00pm
Probe Error - High
02/04/2020 12:30pm
Hot refill to hi probe
time exceeded, Fatal
Probe Error - Low
02/04/2020 12:30pm
Low probe changed state
while hi probe on, Fatal
Probe Error - High
02/04/2020 12:30pm
Hi probe changed state
while lo probe off, Fatal
Probe Error - High
02/04/2020 12:30pm
Cold Fill to hi probe
time excedded, Fatal
Control Temperature
02/04/2020 12:30pm
Controller temperature
exceeded, Fatal
Error Log
Error Details
Error Log
ERROR LOG
Errors are shown in order of newest received. Codes are shown along with date,
time, and description text. Selecting arrow will move to Error Details screen.
Error details will show values 5 seconds before the error (B) and immediately
after the error (A). Time format should match the user setting.
Documents
Error Descriptions
Parts List
12:00pm
Documents
Error Description
12:00pm
Error Desc.
01 - Probe Failure (Fatal)
Probes are out of proper sequence
(Low is off, high is off; High is on,
Low is on)
02 - Overflow Probe Error (Fatal)
During Delime, Overflow probe is
not sensed after xx minutes of
filling
03 - Control Communication Error
IO board to Controller board com-
munication failed
Summary of Contents for GSSP-BL-10G
Page 13: ...13 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL 3E 5E 10E 888 994 7636...
Page 14: ...14 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL 3G 5G 10G 888 994 7636...
Page 15: ...15 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...
Page 16: ...16 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...
Page 17: ...17 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...
Page 18: ...18 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...
Page 19: ...19 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...
Page 20: ...20 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...
Page 21: ...21 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...
Page 22: ...22 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...
Page 34: ...34 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E ELECTRIC CAVITY ASSEMBLY 178201...
Page 35: ...35 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E BASE CAVITY ASSEMBLY 178200...
Page 36: ...36 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3G 5G 10G ELECTRICAL ASSEMBLY 178120...
Page 37: ...37 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3E 5E ELECTRICAL ASSEMBLY 178110...
Page 38: ...38 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E ELECTRICAL ASSEMBLY 178864...
Page 39: ...39 SM GSSP BOILERLESS STEAMER Parts List GSSP BL I O BOARD ASSEMBLY 178115...
Page 40: ...40 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3G 5G HIGH VOLTAGE ELECTRICAL PANEL 178128...
Page 41: ...41 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10G HIGH VOLTAGE ELECTRICAL PANEL 178963...
Page 42: ...42 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3E 5E HIGH VOLTAGE ELECTRICAL PANEL 178126...
Page 44: ...44 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E HIGH VOLTAGE ELECTRICAL PANEL 178127...
Page 45: ...45 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E 480V HIGH VOLTAGE ELECTRICAL PANEL 178962...
Page 46: ...46 SM GSSP BOILERLESS STEAMER Parts List GSSP BL CONTROL PANEL ASSEMBLY 178119...
Page 47: ...47 SM GSSP BOILERLESS STEAMER Parts List GSSP BL PLUMBING ASSEMBLY 178123...
Page 48: ...48 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3G 5G 10G GAS SUPPLY PIPING ASSEMBLY 178122...