background image

OM-CFPC

26

Limited Warranty

To Commercial Purchasers *

(Domestic U.S., Hawaii & 
Canadian Sales Only)

Groen  Foodservice  Equipment  ("Groen  Equipment")  has  been  skillfully  manufactured,  carefully inspected and
packaged to meet rigid standards of excellence. Groen warrants its Equipment to be free from defects in material and
workmanship for (12) twelve months with the following conditions and subject to the following limitations.

I.

This parts and labor warranty is limited to Groen Equipment sold to the original commercial purchaser/users
(but not original equipment manufacturers), at its original place of installation in the continental United States,
Hawaii and Canada.

II.

Damage during shipment is to be reported to the carrier, is not covered under this warranty, and is the sole
responsibility of purchaser/user.

III. Groen, or an authorized service representative, will repair or replace, at Groen's sole election, any Groen

Equipment, including but not limited to, draw-off valves, safety valves, gas and electric components, found
to be defective during the warranty period.  As to warranty service in the territory described above, Groen will
absorb labor and portal to portal transportation costs (time & mileage) for the first twelve (12) months from
date of installation or fifteen (15) months from date of shipment from Groen.

IV. This warranty does not cover boiler maintenance, calibration, periodic adjustments as specified in operating

instructions or manuals, and consumable parts such as scraper blades, gaskets, packing, etc., or labor costs
incurred for removal of adjacent equipment or objects to gain access to Groen Equipment. This warranty does
not cover defects caused by improper installation, abuse, careless operation, or improper maintenance of
equipment.  This warranty does not cover damage caused by poor water quality or improper boiler
maintenance.

V. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR

IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, EACH OF WHICH IS HEREBY EXPRESSLY DISCLAIMED. THE REMEDIES
DESCRIBED ABOVE ARE EXCLUSIVE AND IN NO EVENT SHALL GROEN BE LIABLE FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR THE BREACH OR DELAY IN PERFORMANCE OF
THIS WARRANTY.

VI. Groen Equipment is for commercial use only. If sold as a component of another (O.E.M.) manufacturer's

equipment, or if used as a consumer product, such Equipment is sold AS IS and without any warranty.

* (Covers All Foodservice Equipment Ordered After October 1, 1995)

Summary of Contents for CFPC

Page 1: ...2 Braising Pans Stainless Steel Cabinet Mounted Power Tilting Electrically Heated THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE READ UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED...

Page 2: ...ALL DIRECT CONTACT WITH HOT FOOD OR WATER IN THE BRAISING PAN DIRECT CONTACT COULD RESULT IN SEVERE BURNS WARNING IF THE PAN CONTAINS ITEMS IN SAUCE OR MELTED FAT THEY COULD SLIDE FORWARD SUDDENLY DU...

Page 3: ...R WARNINGS READ FIRST 2 EQUIPMENT DESCRIPTION 4 INSTALLATION 5 INITIAL START UP 5 OPERATION 6 SEQUENCE OF OPERATION 7 CLEANING 8 MAINTENANCE 10 TROUBLESHOOTING 10 PARTS LISTS 12 DIAGRAMS SCHEMATICS 16...

Page 4: ...trol of cooking temperature Turning the thermostat dial starts and stops heating and sets the pan temperature Installation requires two electrical connections 115 Volt service for the tilting actuator...

Page 5: ...eak the cover assembly vent handle Write down the model number serial number and installation date of your unit and keep this information for future reference Space for these entries is provided at th...

Page 6: ...erve local codes and or the National Electrical Code in accordance with ANSI NFPA 70 latest edition 5 Any mechanical or electrical change must be approved by the Groen Food Service Engineering Departm...

Page 7: ...ure loss at a minimum or leave it up to help dry the product Set the thermostat higher to cook or drive moisture off faster The thermostat may be adjusted to any setting in its range to cook exactly a...

Page 8: ...the thermostat switch opens and causes the contactors to open This stops the flow of power to the heating elements and the indicator light As soon as the thermostat senses that the pan is cooling bel...

Page 9: ...ce every 12 hours CAUTION KEEP WATER AND SOLUTIONS OUT OF CONTROLSANDELECTRICALEQUIPMENT DO NOT SPRAY OR HOSE THE CONTROL B O X O R O T H E R E L E C T R I C A L CONNECTIONS THEY ARE NOT WATER PROOF b...

Page 10: ...CAUSE CORROSION k After the unit has been cleaned sanitized and drained let all surfaces air dry unless the unit must be used again right away l It is recommended that the unit be sanitized just befo...

Page 11: ...box REPLACE A BLOWN FUSE ONLY WITH A FUSE OF THE SAME AMP RATING Auth Service Rep Only c For loose or broken wire Y d Thermostat functioning by listening for a click when the switch opens or closes Y...

Page 12: ...OM CFPC 12 Parts List Model CFPC...

Page 13: ...for 208V 012842 8 Spacer Long Rear 012733 25 Heater Strip 1000W for 240 380V 012843 9 Actuator Cover Model 51 014085 26 Heater Strip 1000W for 480V 012908 10 Spring High Pressure 012533 27 Foot Bulle...

Page 14: ...OM CFPC 14 Parts List Model CFPC 2...

Page 15: ...or 380 Volt 054761 8 Pin Actuator Hinge 012525 23 Block Terminal 002577 9 Spacer Front 012528 24 Fuse SC6 6 AMP 003982 10 Ring External Retaining not shown 012529 25 Capacitor 18 F 050384 11 Spring Hi...

Page 16: ...nuary 1 1985 have been wired for three phase power supply The models affected are Size 3 208 Volt Size 3 240 Volt Size 4 208 Volt Size 4 240 Volt If one of these braising pans will be used with single...

Page 17: ...OM CFPC 17 Wiring Diagrams...

Page 18: ...OM CFPC 18 Wiring Diagrams...

Page 19: ...OM CFPC 19 Wiring Diagrams...

Page 20: ...OM CFPC 20 Wiring Diagrams...

Page 21: ...OM CFPC 21 Wiring Diagrams...

Page 22: ...OM CFPC 22 Wiring Diagrams...

Page 23: ...OM CFPC 23 Wiring Diagrams...

Page 24: ...NATIONAL SANITATION FOUNDATION 3475 Plymouth Rd Ann Arbor Michigan 48106 UNDERWRITERS LABORATORIES INC NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NFPA The N...

Page 25: ...______ Serial No ______________________________ Location ________________________________ Date Purchased _________________________ Date Installed ___________________________ Purchase Order No ________...

Page 26: ...portal transportation costs time mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boiler maintena...

Page 27: ...OM CFPC 27 NOTES...

Page 28: ...1055 Mendell Davis Drive Jackson MS 39212 Telephone 601 372 3903 OM CFPC Revised 10 98 FAX 601 373 9587 Part Number 121028...