OM-AH
14
d. Check water level in the jacket to ensure that it
is between minimum and maximum marks on
glass.
e. Close the valve and reinstall the square-head
pipe plug.
f.
Reestablish the jacket vacuum as described in
Paragraph 2, above, if the pressure gauge
does not show a negative reading of 20 to 30
inches mercury (Hg).
4. Water Treatment
WARNING
TO AVOID INJURY, READ AND FOLLOW ALL
PRECAUTIONS STATED ON THE LABEL OF THE
WATER TREATMENT COMPOUND.
a.
b.
Fill a mixing container with the amount of
water required. Use only distilled water.
Following instructions apply to Groen Water
Treatment Kit part number 110324.
i. Hang a strip of pH test paper on the rim
of the container, with about 1 inch of the
strip below the surface of the water.
ii. Stir the water continuously, while you slowly
add water treatment compound until a color
between indicating a pH of 10.5 and 11.5 is
reached. (Shown on the pH test kit chart.)
Judge the pH by frequently comparing the test
strip with the color chart provided in the kit.
Model
Kettle
Capacity
Jacket
Capacity
AH/1E-20
20 Gallons
4.5 Gallons
AH/1E-40
40 Gallons
7 Gallons
AH/1E-60
60 Gallons
9.5 Gallons
AH/1E-80
80 Gallons
11.5 Gallons
AH/1E-100
100 Gallons
11.5 Gallons
iii. Use a measuring cup to add the compound so
that you may record the exact amount used.
iv. The amount may be used again, if the same
water sources and compound are used in the
future. However, it is best to check the pH
each time treated water is prepared.
Troubleshooting
Your Groen kettle is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of
checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel and in this manual.
If an
item on the list is followed by , the work should be done by a qualified service representative.
WARNING
BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY
AND CLOSE THE MAIN GAS VALVE. ALLOW FIVE MINUTES FOR UNBURNED GAS TO VENT.
CAUTION
USEING REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED
DISTRIBUTOR CAN CAUSE OPERATOR INJURY AND EQUIPMENT DAMAGE AND WILL VOID ALL WARRANTIES.
SYMPTOM
WHO
WHAT TO CHECK
indicates items which must be performed by an authorized technician.
Kettle continues heating after it
reaches desired temperature.
User
a. Thermostat dial setting.
Auth
Service
Rep Only
b. Thermostat calibration.
c. Thermostat operation. The thermostat should click when the dial is
rotated to settings above and below the temperature of the kettle.
Kettle stops heating before it
reaches the desired temperature.
User
a. Thermostat dial setting.
Auth
Service
Rep Only
b. Thermostat calibration.
c. Thermostat operation. The thermostat should click when the dial is
rotated to settings above and below the temperature of the kettle.