Use sponge, cloth or plastic brush to clean the

kettle.

Scrapers or steel wool can harm the kettle surface.

detergent solution. To make washing easier,

let the detergent solution sit in the kettle and

soak into the  residue, or warm the detergent

solution  briefly.  Do not use any metal

material (like metal sponges) or metal  (like a

spoon, scraper, or wire brush) that might

scratch the surface.  Scratches make the

surface hard to clean and provide places for

bacteria to grow.  Do 

not

 use steel wool,

which may leave particles imbedded in the

surface and cause eventual corrosion and

pitting.

h. The outside of the unit may be polished with a

recognized stainless steel cleaner. 

i.

When the equipment needs to be sanitized,

use a sanitizing solution equivalent to one that

supplies 200 parts per million chlorine.  Obtain

advice on the best sanitizing agent from your

supplier of sanitizing products. 

j.

Following the supplier’s instructions, apply the

sanitizing agent, after the unit has been

cleaned and drained.  Rinse off the sanitizer

thoroughly. 

k. It is recommended that the unit be sanitized

just  before use.

l.

If there is difficulty removing mineral deposits or

a film left by hard water or food residues, clean

the kettle thoroughly. Then use a de-liming

agent, such as Groen De-limer De-Scaler (Part

Number 114800).  Rinse and drain the unit 

thoroughly before further use.

  

m. If especially difficult cleaning problems  persist,

contact your cleaning product  supplier for

assistance. The supplier has a trained technical

staff with laboratory facilities to serve you.

Maintenance 

NOTICE: Contact Groen or an authorized Groen Service Representative when repairs are required.

A Service Log is provided at the rear of this manual.

Each time service is performed on this Groen

equipment, enter the date on which the work was

done, and who did it.  Keep this manual with the

equipment.

1.  Jacket Vacuum/Removing Air from Jacket

 

When the kettle is cold, a positive pressure/ vacuum

gauge reading or a reading near zero indicates that

there is air in the jacket. Air in the jacket acts as an

insulator, and slows kettle heating.

To remove air:

a. Start the unit. (Be sure there is water or product

in the kettle when heating).

b. When the pressure/vacuum gauge reaches a

positive pressure reading of five PSI, release

the trapped air and steam by pulling up the

safety valve ring for about five seconds. Repeat

this step three or four times.  Then let the pull

ring snap back into the closed position.

c. If there is little discharge (mostly air), and the

pressure gauge drops back to zero PSI, allow

the pressure to build back to five PSI and

repeat the procedure.

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Summary of Contents for AH/1

Page 1: ...CINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS...

Page 2: ...BRANES AND CLOTHING TAKE PRECAUTIONS WEAR RUBBER GLOVES GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING CAREFULLY READ WARNINGS AND FOLLOW DIRECTIONS ON CLEANER LABELS NOTICE NEVER LEAVE A SANITIZER IN...

Page 3: ...hio 44131 ANSI Z83 11 NATIONAL SANITATION FOUNDATION 3475 Plymouth Rd Ann Arbor Michigan 48106 NSF ANSI 4 AMERICAN NAT L STANDARDS INST INC 1430 Broadway New York New York 10018 Z223 1 1984 National F...

Page 4: ...what is happening inside the unit These are a Water level sight glass Indicates whether there is enough water in the steam jacket b Pressure vacuum gauge Shows steam pressure and whether too much air...

Page 5: ...damage Open the container and check the unit for hidden damage Report shipping damage or shipment errors to the delivery agent Write down the model number serial number and installation date for your...

Page 6: ...above Securely fasten the screw to attach draft directly Do not change the diverter in any way WARNING DO NOT ATTACH THE UNIT TO A TYPE B VENT FAILURE COULD RESULT IN FIRE OR PROPERTY DAMAGE Install...

Page 7: ...ng system at test pressures equal to or less than 1 2 PSIG 3 48 kPa 16 Check the following points to confirm that your AH kettle has been installed properly electrical or gas type change must be appro...

Page 8: ...TO LIGHT ANY BURNER WITH A FLAME CAUTION HEATING AN EMPTY KETTLE MAY CAUSE THE RELEASE OF STEAM FROM THE SAFETY VALVE 1 To Start Kettle a CHECK THE WATER LEVEL IN THE JACKET EVERY DAY The level shoul...

Page 9: ...TIRRING OR TRANSFERRING PRODUCT TO ANOTHER CONTAINER CAUTION DO NOT OVERFILL THE KETTLE WHEN COOKING HOLDING OR CLEANING KEEP LIQUIDS 2 3 5 8 cm BELOW THE KETTLE RIM TO ALLOW CLEARANCE FOR STIRRING BO...

Page 10: ...urn off the power switch Check the gas supply valves and wait five minutes before trying again by switching power on If you cannot establish a pilot flame in four tries close all valves turn off the p...

Page 11: ...CONTACT CAN CAUSE CORROSION c Prepare a solution of the detergent cleaning compound as instructed by the supplier Clean the unit thoroughly A cloth moistened with cleaning solution can be used to cle...

Page 12: ...as Groen De limer De Scaler Part Number 114800 Rinse and drain the unit thoroughly before further use m If especially difficult cleaning problems persist contact your cleaning product supplier for as...

Page 13: ...ng a will screwdriver or other implement to pull the ring help you avoid contact with the steam 3 Jacket Filling Every day before you turn on the unit make sure the water level is approximately in the...

Page 14: ...s and compound are used in the future However it is best to check the pH each time treated water is prepared Troubleshooting Your Groen kettle is designed to operate smoothly and efficiently if proper...

Page 15: ...is not flowing 1 Check the pilot gas line for kinks and obstructions 2 Clean orifice if necessary 3 Check magnetic operator for pilot valve on gas valve Repair or replace as necessary d That the pilo...

Page 16: ...OM AH 16 Parts List AH 1E PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Page 17: ...T x Close 008877 Screw Sheet Metal pan hd 12 x 1 2 lg 008769 Valve Gate 1 2 NPT 004180 Bracket faucet Mounting 16 Ga x 4 3 4 009054 Label Warning 098171 Diverter Draft 6 AH 1E 20 40 012474 Wiring Diag...

Page 18: ...OM AH 18 Parts List AH 1E 40 PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Page 19: ...281 Orifice Prop Higher Elev 000403 9 Bracket Pilot Burner Mounting 123824 11 Bracket Pilot Burner Mounting 123824 10 Screw 10 24 x 3 8 lg Round Head 006009 12 Screw 10 24 x 3 8 lg Round Head 006009 1...

Page 20: ...mbly Front Panel Components Assembly Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description and number quantity and where applicable voltag...

Page 21: ...Screw 10 32 x 3 8 long 069773 12 Sight Tube 5 8 Dia x 4 3 4 long 008742 Electrical Panel Assembly 123823 13 Fittings Sight Glass Assembly 002845 1 Water Level Control 24V 122192 Front Panel Component...

Page 22: ...OM AH 22 Electrical Schematic PDF compression OCR web optimization using a watermarked evaluation copy of CVISION PDFCompressor...

Page 23: ...tion ___________________________________ Date Purchased _____________________________ Date Installed _______________________________ Purchase Order No __________________________ For Service Call _____...

Page 24: ...from date of shipment from Groen IV This warranty does not cover boiler maintenance calibration periodic adjustments as specified in operating instructions or manuals and consumable parts such as scra...

Reviews: