IMPORTANT — READ FIRST — IMPORTANT

WARNING: THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY

AND PLUMBING.  IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR
DAMAGE TO THE EQUIPMENT.  THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH
APPLICABLE CODES.

CAUTION:

SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.

CAUTION:

DO NOT INSTALL THE UNIT IN ANY WAY WHICH WILL BLOCK THE RIGHT SIDE VENTS,
OR WITHIN 12 INCHES OF A HEAT SOURCE SUCH AS A BRAISING PAN, FRYER, CHAR
BROILER OR KETTLE.

CAUTION:

LEVEL THE UNIT FRONT TO BACK, OR PITCH IT SLIGHTLY TO THE REAR, TO AVOID
DRAINAGE PROBLEMS.

WARNING: TO AVOID DAMAGE OR INJURY, FOLLOW THE WIRING DIAGRAM EXACTLY WHEN

CONNECTING A UNIT.

CAUTION:

DO NOT USE PLASTIC PIPE.  DRAIN MUST BE RATED FOR BOILING WATER.

WARNING: DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN.

WARNING: BLOCKING THE DRAIN IS HAZARDOUS.

IMPORTANT:

Improper drain connection will void warranty.

IMPORTANT:

Do not allow any water traps in the line.  A trap can cause pressure to build up inside the
cavity during steaming, which will make the door gasket leak. 

WARNING: WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF THE UNIT. 

STEAM CAN CAUSE BURNS.

WARNING: BEFORE CLEANING THE OUTSIDE OF THE STEAMER, DISCONNECT THE ELECTRIC POWER

SUPPLY.  KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL
COMPONENTS. NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT.

WARNING: ALLOW COOKING CHAMBER TO COOL BEFORE CLEANING.

WARNING: CAREFULLY READ THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF EACH

CLEANING AGENT.

  

  USE SAFETY GLASSES AND RUBBER GLOVES AS RECOMMENDED BY

DELIMING AGENT MANUFACTURER.

WARNING: DO NOT MIX DE-LIMING AGENTS (ACID) AND DE-GREASERS (ALKALI).

WARNING: DO NOT PUT HANDS OR TOOLS INTO THE COOKING CHAMBER UNTIL THE FAN HAS

STOPPED TURNING.

WARNING: 

DO NOT OPERATE THE UNIT UNLESS THE REMOVABLE RIGHT SIDE PANEL HAS BEEN

RETURNED TO ITS PROPER LOCATION.

NOTICE:

DO NOT USE A CLEANING OR DE-LIMING AGENT THAT CONTAINS ANY SULFAMIC ACID

OR ANY CHLORIDE, INCLUDING HYDROCHLORIC ACID.  IF THE CHLORIDE CONTENT OF
ANY PRODUCT IS UNCLEAR, CONSULT THE DISTRIBUTOR OR MANUFACTURER.

NOTICE:

DO NOT USE ANY DE-GREASER THAT CONTAINS POTASSIUM HYDROXIDE OR SODIUM

HYDROXIDE OR THAT IS ALKALINE.

WARNING: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR

AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY
TO THE OPERATOR AND DAMAGE THE EQUIPMENT.  SERVICE BY OTHER THAN FACTORY-
AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.

WARNING: HIGH VOLTAGE EXISTS INSIDE CONTROL COMPARTMENTS. DISCONNECT FROM BRANCH

BEFORE SERVICING.  FAILURE TO DO SO CAN RESULT IN SERIOUS INJURY OR DEATH.

Summary of Contents for (2)CC10-GF

Page 1: ...S IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS S...

Page 2: ...DE OF THE STEAMER DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNING ALLOW COOKING...

Page 3: ...UIPMENT DESCRIPTION 4 INSPECTION AND UNPACKING 5 WATER CONDITIONING REQUIREMENTS 6 INSTALLATION 7 INITIAL START UP 11 OPERATING INSTRUCTIONS 13 CLEANING 19 MAINTENANCE 26 TROUBLESHOOTING 26 DIAGRAMS A...

Page 4: ...the unit and touch pads to select the mode of operation and to switch on power A digital readout shows the selected temperature which is entered by turning a dial Pilot burner status is shown by a lig...

Page 5: ...m the skid Pull the carton up off the unit Be careful to avoid personal injury or equipment damage from nails and sharp pieces of wood or staples which might be left in carton walls Write down the mod...

Page 6: ...le water 30 40 ppm TDS 2 If your water contains scale forming minerals as most water does use a well maintained water softener Whether an exchangeable softener cartridge or a regenerating system is ch...

Page 7: ...al manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than PSI 3 45 kPa 2 Gas Supply Connections WARNING THIS UNIT IS FOR COMMERCIAL U...

Page 8: ...Connection a Unit Without Drain Tank A 1 inch 4 cm ID CC10 G or 2 inch 5 cm ID hose CC20 G may be attached to the supplied drain outlet with a clamp Do not use plastic pipe because the drain must with...

Page 9: ...OM CC G 9 Convection Combo Utility Connections NOTE Remove right side panel to make connections at terminal block in rear of control compartment...

Page 10: ...OM CC G 10 Proper Drain Line Connections...

Page 11: ...or ignition During initial start up the pilot may require several trials in order to bleed air from the gas piping Subsequent start up should only require about five seconds to achieve ignition NOTE S...

Page 12: ...8 To Test Combo Mode Operation turn on the p o w e r a nd clear any time from the timer display Press the COMBO touch pad Set the COOK temperature to 350o F 175o C The WAIT light will come on It will...

Page 13: ...ime values c CLEAR Pressing this touch pad once stops the beeper and resets the timer to the time that was last set Pressing twice clears it to 00 00 At the end of a cooking period opening the door is...

Page 14: ...OM CC G 14 Operation Standard Operating Controls...

Page 15: ...NOTE You cannot change operating modes while the timer is running c The unit will be in the mode of operation in which it was last used Because of this the indicator light for that mode will be lit If...

Page 16: ...me to zero by either 1 opening the door and pressing CLEAR or pressing CLEAR twice A new cooking time may then be set by using the number keys 2 Oven Mode a To use the Convection Combo as a convection...

Page 17: ...hen you turn on the power see the Troubleshooting section If the door is closed and the cooking temperature is above 200o F 93o C the fan will begin to operate b If the power is already on and there i...

Page 18: ...o stop cooking take the pans out of the oven using hot pads or oven mitts to protect your hands from the hot pans The unit will continue steaming and heating the oven at the set temperature until the...

Page 19: ...r C Single CC10 G Units NOTE For instructions about cleaning the interior of double stacked CC10 G units or any CC20 G units go directly to Section D below PRECAUTIONS WARNING DISCONNECT THE POWER SUP...

Page 20: ...de limer solution Remember if the HOT light is on use the Fast Cool method to reduce the temperature The timer display will show CC or CL c Step 3 Cooking Chamber WARNING BEFORE REACHING INTO THE OVE...

Page 21: ...d to engage the four hooks to their support posts If absolutely necessary you may remove the wire rack support Left The left partition includes a back plate and an air distribution baffle Push down to...

Page 22: ...r halting the Clean Cycle and before you cook any food be sure to thoroughly wash out all chemical residue by filling and draining the steam generator Enter Steam Mode and wait 60 to 90 seconds to fil...

Page 23: ...mer and press the mode s touch pad Remove the cap from the fill port located on the front of the stand directly below the control panel Add de liming solution to the fill tank When using Lime A Way or...

Page 24: ...tion has a small circular pattern of drain holes Place it directly down onto the four support posts Right The right partition includes a large circular flared opening that must be centered in front of...

Page 25: ...e tubes and walls behind the partitions The racks and partitions may be rinsed in a sink f Step 6 Cooking Chamber and or De liming When the Clean Cycle is complete the display will read 00 00 WARNING...

Page 26: ...lid State Controls If problems persist call an authorized Groen Service Agency If the controls stop responding to normal commands or the unit is behaving oddly reset the controls using the following p...

Page 27: ...ice Agency 7 Out of Calibration Units Before 3 97 Only The unit will operate in all modes Call your Groen Service Agency 7A Time Between Fills Units After 3 97 Only Check for a leaky fill valve The un...

Page 28: ...OM CC G 28 Diagrams Schematics...

Page 29: ...3 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NFPA 70 The National Electrical Code NATIONAL SANITATION FOUNDATION 3475 Plymouth Road Ann Arbor...

Page 30: ...OM CC G 30 Service Log Model No Serial No Date Purchased Purchase Order No Purchased From Location Date Installed For Service Call Date Maintenance Performed Performed by...

Page 31: ...tal to portal transportation costs time and mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boile...

Page 32: ...1055 Mendell Davis Drive Jackson MS 39212 Telephone 601 372 3903 Fax 601 373 9587 OM CC G Revised 7 00 Part Number 121020 Rev A...

Reviews: