-10-
Model H8178 Power Feed
4.
Locate the X-axis lead screw half-nut (see
Figure 4
).
5.
Adjust both cap screws until the handwheel
has approximately 0.003" backlash as shown
by the dial.
Figure 4.
X-axis leadscrew backlash
adjustment.
Lead
Screw
Lead Screw Half-Nut
Milling Table
6.
Use the #1 Phillips screwdriver to remove the
four flat head screws from both ends of the
power feed.
7.
Carefully slide the motor and mounting plate
from the housing a few inches as shown in
Figure 5
.
8.
Carefully slide the circuit board and vent
cover from the housing a few inches as
shown in
Figure 5
.
Figure 5.
Power feed breakdown.
Figure 6.
Cap removal.
10.
Use a 5mm hex wrench, remove the two end
plate retaining cap screws (
Figure 6
).
11.
Thread the cap screws into the power feed
mounting holes (
Figure 7
), and in an alternat-
ing fashion, tighten the screws to remove the
table end plate.
Figure 7.
End plate removal.
Half-Nut Cap Screws
Circuit Board
Motor and Mounting Plate
9.
Using a standard screwdriver, pry the
leadscrew dust cap off (
Figure 6
).
End Plate
Retaining
Cap Screw