Model G0954/55/56/57 (Mfd. Since 11/21)
-17-
Figure 13. Location of pressure switch cover flat
head screw (G0957 shown).
Pressure
Switch
Cover
G0957 Only: Remove flat head screw shown
in
Figure 13 to remove pressure switch
cover.
4. Connect incoming power wires to LINE and
ground terminals shown in
Figure 15.
Figure 15. Incoming power wires connected to
LINE and ground terminals.
LINE
MOTOR
GND
G0954/G0955/G0956
INCOMING
POWER WIRES
OUTGOING
MOTOR WIRES
During next step, make sure incoming
ground wire is connected to correct terminal
to ensure machine will be properly grounded
(see "GND" in Figure 15). An ungrounded or
improperly grounded machine can cause
electrocution if live electrical wires make
contact with parts touched by operator.
3. Cut a hole in pressure switch strain relief,
then insert incoming power conduit through
strain relief (see
Figure 14).
Figure 14. Location of pressure switch strain
relief (G0956 shown).
5. Install pressure switch cover.
Strain
Relief
G0957
INCOMING
POWER WIRES
OUTGOING
MOTOR WIRES
MOTOR
LINE
+
_
P
GND
GND