![Grizzly G0954 Owner'S Manual Download Page 18](http://html.mh-extra.com/html/grizzly/g0954/g0954_owners-manual_2265980018.webp)
-16-
Model G0954/55/56/57 (Mfd. Since 11/21)
Anchoring to Floor
Lag shield anchors with lag screws (see below)
are a popular way to anchor machinery to a con-
crete floor, because the anchors sit flush with the
floor surface, making it easy to unbolt and move
the machine later, if needed. However, anytime
local codes apply, you MUST follow the anchoring
methodology specified by the code.
Machine Base
Concrete
Lag Screw
Lag Shield Anchor
Flat Washer
Drilled Hole
Figure 11. Popular method for anchoring
machinery to a concrete floor.
Anchoring to Concrete Floors
Number of Mounting Holes ............................ 3
Diameter of Mounting Hardware ................
5
⁄
16
"
Anchoring machinery to the floor prevents tipping
or shifting and reduces vibration that may occur
during operation, resulting in a machine that runs
slightly quieter and feels more solid. Since this
machine is extremely top heavy, anchoring it
to the floor will also prevent injury and property
damage.
If the machine will be installed in a commercial or
workplace setting, or if it is permanently connect-
ed (hardwired) to the power supply, local codes
may also require that it be anchored to the floor.
IMPORTANT: DO NOT tighten lag screws so
much that they may cause stress to the tank.
Tip: Install vibration pads between the lag screws
and floor to further cut down on vibration and
noise.
Before the machine can be connected to the
power source, an electrical circuit and connec-
tion device must be prepared per the
POWER
SUPPLY section in this manual; and all previous
setup instructions in this manual must be com-
plete to ensure that the machine has been assem-
bled and installed properly. The disconnect switch
installed by the electrician (as recommended) is
the primary means for disconnecting or connect-
ing the machine to the power source.
Power Connection
To connect incoming power wires:
1. DISCONNECT POWER SUPPLY WIRES
OR LOCK DISCONNECT SWITCH BOX IN
OFF POSITION!
2. G0954/G0955/G0956 Only: Remove Phillips
head screw shown in
Figure 12 to remove
pressure switch cover.
Figure 12. Location of pressure switch cover
Phillips head screw (G0956 shown).
Pressure
Switch
Cover
Connecting Incoming Power Wires
Items Needed
Qty
Phillips Head Screwdriver #2 ............................ 1
Scissors ........................................................1 Pr.
Connecting power supply wires to machine
without first disconnecting power supply
may result in serious injury or death.