-18-
Model G0954/55/56/57 (Mfd. Since 11/21)
Test Run
Once assembly is complete, test run the machine
to ensure it is properly connected to power and
safety components are functioning correctly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from
power, and fix the problem BEFORE operating the
machine again. The
Troubleshooting table in the
SERVICE section of this manual can help.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpect-
ed results that can lead to serious injury,
death, or machine/property damage.
Serious injury or death can result from
using this machine BEFORE understanding
its controls and related safety information.
DO NOT operate, or allow others to operate,
machine until the information is understood.
Eye injury hazard! Always
wear safety glasses when
handling pressurized air
system.
The Test Run consists of verifying the following:
1) The compressor oil level is sufficient, 2) the
motor powers up and runs correctly, 3) the motor
and pump turn
OFF when the cut-out pressure
is reached, and 4) the safety relief valve works
correctly.
Figure 16. Connecting power to machine.
Move the disconnect switch handle to the ON
position, as illustrated below. The machine is now
connected to the power source.
Connecting to Power Source
Figure 17. Disconnecting power from machine.
Move the disconnect switch handle to the OFF
position, as illustrated below. The machine is now
disconnected from the power source.
Note: Lock the switch in the OFF position to
restrict others from starting the machine.
Disconnecting from Power Source
Summary of Contents for G0954