Model G0888 (Mfd. Since 01/19)
-23-
Cleaning/Replacing
Filter
The pleated air filter needs regular cleaning.
Replace every 300 hours or when airflow per-
formance becomes noticeably reduced despite
cleaning.
1. DISCONNECT MACHINE FROM POWER!
2. Wear NIOSH-approved respirator, ANSI-
approved goggles, and protective gloves
while handling filter.
3. Completely remove filter drawer (see Figure
26).
Wear ANSI-approved safety goggles, a
NIOSH-approved respirator, and protec-
tive gloves when removing, cleaning, and
replacing filter. Carefully minimize amount
of dust allowed to become airborne, and
prevent spread of dust onto hands or cloth-
ing. Dispose of all waste properly according
to local regulations for material type.
4. Pull filter straight up out of drawer, and take
note of airflow direction.
5. Replace filter, then insert drawer into machine
stand.
Figure 26. Air filter and components.
Always clean filter outdoors when possible!
However, take special care to avoid contaminat-
ing the environment. When cleaning filter, always
inspect for damage and replace filter if ANY dam-
age or tears are found.
Initially clean filter by carefully tapping caked-
on dust into an enclosed container to minimize
release of dust into the air, then follow the instruc-
tions provided below.
IMPORTANT: DO NOT use compressed air to
clean filter—especially if indoors—as it will likely
cause a large amount of fine dust to become air-
borne.
Clean with a soft bristle brush and vacuum with a
shop vacuum equipped with a HEPA filter.
Cleaning Filter