-20-
Model G0836 (Mfd. Since 09/17)
5. Turn spindle speed dial clockwise (see
Figure 17) to turn machine ON. Verify motor
starts up and runs smoothly without any
unusual problems or noises.
6. Press Emergency Stop button to turn machine
OFF (see Figure 17).
Figure 17. Test run controls.
Spindle Speed Dial
Emergency
Stop Button
7. Rotate spindle speed dial all the way counter-
clockwise to "0" position. WITHOUT resetting
Emergency Stop button, try to start machine
by rotating spindle speed dial clockwise. The
machine should not start.
— If the machine does not start, the safety
feature of the Emergency Stop button is
working correctly. Congratulations! The
Test Run is complete.
— If the machine does start, immediately
turn it
OFF and disconnect power. The
safety feature of the Emergency Stop but-
ton is NOT working properly and must be
replaced before further using the machine.
Power Feed Test Run
This mill/drill comes with a power feed unit for
X-axis table travel (see
Figure 18). A limit switch
and adjustable table limit stops (see
Figure 19)
attached to the front of the table control its travel
and are important to the proper operation of this
power feed unit.
If the power feed does not operate as expect-
ed during the test run, immediately stop the
machine, disconnect it from power, and fix the
problem BEFORE operating the machine again.
The Troubleshooting table in the SERVICE sec-
tion of this manual can help.
Figure 18. G0836 power feed controls.
Leadscrew
Selector
Knob
Speed
Control Dial
Power
Indicator
Fault
Indicator
Direction
Switch
3. Rotate spindle speed dial all the way counter-
clockwise to the "0" position. This will prevent
spindle from starting at a high speed.
4. Turn FWD/REV switch to FWD position.
Figure 19. X-axis table lock, leadscrew selector
knob, table limit stops, and limit switch.
X-Axis
Table Lock
Leadscrew
Selector Knob
Table
Limit
Stops
Limit
Switch