-6-
Model G0808 (Mfd. Since 11/15)
Power Feed Identification
Model G0808 is equipped with power feed units
for X- and Z-axis table movement. Refer to
Figures 6 and 7 and the following descriptions to
understand the functions of the various compo-
nents of the power feed system.
AA. Reset Button: Resets internal circuit breaker
if unit is overloaded and shuts down.
AB. Directional Lever: Selects direction of table
movement. Center position is neutral.
AC. X-Axis Limit Stop (1 of 2 Shown): Limits
X-axis table travel.
AD. Limit Switch: Stops powered table move-
ment when switch comes in contact with
either limit stop.
AE. Rapid Traverse Button: When pressed,
moves table at full speed when already in
motion.
AF. Speed Dial: Controls speed of table move-
ment. Turning dial clockwise causes table to
move faster.
Note: Feed rates for table travel are extremely
difficult to precisely calculate. We recom-
mend that you combine research and experi-
mentation to find feed rates that best work for
your operations.
AG. ON/OFF Switch: Enables/disables power to
unit.
AH. Z-Axis Limit Stop (1 of 2 Shown): Limits
Z-axis table travel.
Figure 6. X-axis power feed controls.
AC
AB
AA
AD
AG
AF
Figure 7. Z-axis power feed controls.
AD
AH
AG
AF
AB
AE
AE
AA