-36-
G0783 (Mfd. Since 05/15)
Wiring Diagram
CONTACTOR
Telemecanique
220V
Ground
TOP
VIEW
(Bottom)
1
O
W
N
O
(Top)
2
6
10
1
5
9
1L1
3L2
5L3
13NO
A1
TRANSFORMER
NC
V
LC1K
0910
50/60 HZ
CanSen
HZ5D-20
IEC60947-3
GB14048.3
1
2
LW26-20 AC-23A
POWER: 20VA
TC
L1 U
LEVER
POWER
BUTTON
ONPOW
LAS1-A SERIES
5A/220VAC
5A/250VAC
L2
L2
L1
N
L1
PE
1
1
W
V
U
TO
MOTOR
(220V 3-Ph)
2T1
4T2
6T3
14NO
A2
JEM1-0-1
20A 3-Phase
2F99523016
Telemecanique
ZB2-BE102C
AC 15 240V - 3A
CanSen
U1
W1
N
L1
L1
2
6
10
14
1
5
9
13
16
12
8
4
7
3
11
15
1
ROTARY SWITCH
EMERGENCY STOP BUTTON
L3
3
7
11
4
8
12
(Top)
(Bottom)
W2
V2
U2
U1
W1
L3
V1
V1
U2
W2
V2
The motor wiring shown here is
current at the time of printing, but it
may not match your machine.
Always use the wiring diagram
inside the motor junction box.
PUMP MOTOR
220V 3-Ph
MASTER
POWER SWITCH
MPP225K 2H
80821321 F
Capacitor
Ground
Hot
Hot
15-15 Plug
(as recommended)
220 VAC
3-Phase
W
Z
G
X
Hot
Summary of Contents for G0783