-74-
Model G0764Z (Mfd. Since 10/15)
Blade Tilt Calibration
The blade tilt stops are calibrated at the factory,
but they can be recalibrated if they change during
the life of the machine. The 0° stop positions the
blade square to the table.
Tools Needed
Qty
Hex Wrench 3mm .............................................. 1
Machinist's Square, 90° & 45° ........................... 1
0° Stop
1. DISCONNECT MACHINE FROM POWER!
2. Move blade tilt to 0° and raise main blade as
high as it will go.
3. Open cabinet door and identify the stop nuts
shown in
Figure 150.
4. Use machinist's square to check if main blade
is square to table (see
Figure 151).
Figure 152. Tilt scale cable hex nuts.
Tilt Scale
Cable Hex Nuts
Figure 150. Blade tilt stop nuts.
0° Stop
Nut
45° Stop
Nut
a. If main blade is not square to table,
loosen the two set screws on 0° stop
nut, then loosen stop nut away from
leadscrew collar.
b. Adjust main blade tilt angle so that it is
square to table.
c. Thread 0° stop nut against leadscrew col-
lar and retighten set screws.
45° Stop
Use a similar procedure for the 45° stop nut
shown in
Figure 150, as previously instructed for
the 0° stop nut.
Tilt Scale Calibration
If necessary, the blade tilt scale on the front of the
saw can be adjusted by using the hex nuts shown
on the tilt scale cable in
Figure 152. These are
accessed inside the cabinet.