![Grizzly G0764Z Owner'S Manual Download Page 42](http://html1.mh-extra.com/html/grizzly/g0764z/g0764z_owners-manual_2267763042.webp)
-40-
Model G0764Z (Mfd. Since 10/15)
3. Connect ground wire, then connect incoming
power wires to bottom terminals shown in
Figure 69.
Figure 69. Terminal locations to connect
incoming power wires and ground wire.
Incoming Power
Terminals
4. Make sure wires have enough slack so they
are not pulled tight or stretched.
5. Re-install junction box cover, and perform
Test Run in following section to check phase
polarity.
Ground
Terminal
Make sure incoming ground wire is con-
nected to right-most terminal post in the
power junction box so machine is properly
grounded. An ungrounded or improperly
grounded machine may have an electrified
frame which could cause electrocution
when touched.