Model G0555LX
(Mfd. Since 1/14)
-11-
3. Remove the two wire nuts from the wires
shown in
Figure 3.
4. Re-wire the motor as shown in Figure 3.
5. Tighten all wire nuts and secure them with
electrical tape so they cannot vibrate loose
during motor operation.
6. Install the 6-15 plug on the power cord per
the plug manufacturer's instructions.
Ground
Ground
Motor
Pre-wired
for 110V
Motor
Rewired
for 220V
Figure 4. Motor rewired for 220V.
Figure 3. Motor pre-wired for 110V.
Ground
Ground
Motor
Pre-wired
for 110V
Motor
Rewired
for 220V
Remove
Remove
The voltage conversion MUST be performed by
an electrician or qualified service personnel. The
voltage conversion procedure consists of rewiring
the motor and installing the correct plug. The nec-
essary wiring diagrams are provided in the
Wiring
section, beginning on
Page 55 for your reference.
IMPORTANT: If the diagram on the motor con-
flicts with the diagrams in the
Wiring section, the
motor may have changed since the manual was
printed. Use the diagram on the motor instead.
Items Needed
Qty
•
Phillips Head Screwdriver #2 ..................... 1
•
Electrical Tape ............................ As Needed
•
Wire Nut 14 AWG ....................................... 1
•
NEMA Plug 6-15 ......................................... 1
•
Wire Cutters/Stripper .................................. 1
Converting Voltage
to 220V
For your own safety and protection of
property, consult an electrician if you are
unsure about wiring practices or electrical
codes in your area.
To convert the machine to 220V:
1. DISCONNECT MACHINE FROM POWER!
2. Remove the 5-15 plug from the cord.
Summary of Contents for G0555LX