G0532 2HP Dry Spray Booth
-21-
6.
With new filters installed, turn the spray booth
ON
,
observe the rise in the reading, and mark
with the supplied green arrow, as shown in
the example in
Figure 25
.
Figure 25.
New filter installation mark example.
7.
Multiply the reading from
Step 6
times 2 (2x)
and mark with the supplied red arrow (
Figure
26
). This is the dirty filter indicator mark.
When the fluid reaches the red arrow, install
new filters.
Figure 26.
Dirty filter mark example.
Note:
Always make sure the fluid level is at
zero before using the spray booth each time.
Also, check the fluid level on a regular basis
and re-fill as needed.
Dirty Filter
Indicator
Mark
New Filter
Indicator
Mark