background image

3.2 Mounting position

KALEIDO is fitted with a support
base which allows a steady position on
the floor or attached to a trussing
system. 

The KALEIDO unit must not be
hung upside down

Both fixing yoke and support base
allow a complete movement of 180° to
help easy installation.
Minimum distance from flmmable
objects must be 0.5m so as to make air
circulation easy.

3.3 Mounting

4 11mm Ø holes (180x180 mm wheelbase) are provided in
the support base to fix the lantern to the ceiling or to the
floor. One 12,5 mm Ø hole screw nut is also available in
the middle of the support base and the yoke to hang or fix
the projector (see pict.1 and 2). 

3.4 leaf barndoor set up

Take the glass safety grid off the unit by removing the 6 M4
screws and replace it with the 4 leaf barndoor set fixing it
again with the 6 screws. Further 4 holes have been provided
to fix the 4-leaf barndoor and the glass panel together to the
unit by 4 M3x10 screws.

3.5 Electrical connection

1) Cable the mains plug with a supply cable 3x1.5 mm

2

minimum and a 2-pin + GND plug;
2) Connect the lantern to a mains supply of 230V -
50/60Hz.
3) Ensure that the mains cable is connected to earth; 
4) the line safety thermoswitch must have the following
characteristics:

rated for (In) 20A - sensitivity (Id) 0,03 A.

5) The unit is provided with power factor correction.

11

pict.1

pict.3

pict.2

NO

YES

Summary of Contents for KALEIDO GR 0410 MSD 575 W

Page 1: ...Foglio di Istruzioni Instructions KALEIDO GR 0410 MSD 575 W FI 0410 Rev 02 27 09 06...

Page 2: ...unzionamento con DMX 6 4 2 Funzionamento in automatico 7 4 3 Master Slave 8 5 0 MANUTENZIONE 8 6 0 INFORMAZIONI TECNICHE 9 7 0 PARTI DI RICAMBIO 9 INDEX INDEX Page 1 0 PACKING 10 2 0 SAFETY 10 3 0 INS...

Page 3: ...roiettore ed alla struttura di sospensione dello stesso per evitare la caduta accidentale del proiettore nel caso poco probabile che il punto di fissaggio primario dovesse cedere 3 0 INSTALLAZIONE DEL...

Page 4: ...utilizzare anche il foro 12 5 posto al centro della staffa come mostra la figura 1 3 4 Installazione del paraluce Per installare il paraluce fig 2 sul proiettore necessario svitare le 6 viti M4 testa...

Page 5: ...pendent setting Permette di settare l accensione della lampada e il dimmer su un indirizzo personalizzato Per selezionarlo premere Select dopo avere impostato su ON l opzione 4 il display mostra l ind...

Page 6: ...canali a seconda delle opzioni scelte La connessione delle prese XLR 3 poli dovr avvenire come di seguito descritto vedi fig 1 pin 1 function GND SHIELD pin 2 function SIGNAL pin 3 function SIGNAL Ver...

Page 7: ...nte SELECT il display mostrer SP 1 Agite sui tasti e per regolare la velocit La durata dei tempi descritta in tab 2 E possibile regolare la durata di una scena colore premendo il pulsante SELECT il di...

Page 8: ...specchi e i dicroici poich persino un sottilissimo strato di polvere pu ridurre in modo sostanziale la resa luminosa ed alterare la compattezza del fascio sostituite gli specchi e i dicroici se hanno...

Page 9: ...a ottico Gruppo ottico a riflettori piani brevettato Fusibile per lampada 6x30 250V 10A Fusibile per elettronica 5x20 250V 3 25A Temperatura massima di esercizio 130 C Temperatura ambiente massima 40...

Page 10: ...strongly recommended that a safety chain or wire is attached to this projector and secured to the main mounting framework to arrest the fall of the unit in the unlikely event that the primary mountin...

Page 11: ...base and the yoke to hang or fix the projector see pict 1 and 2 3 4 leaf barndoor set up Take the glass safety grid off the unit by removing the 6 M4 screws and replace it with the 4 leaf barndoor se...

Page 12: ...controller DMX 4 Dimmer shutter lamp On Off Independent setting To enter this option push SELECT after you have set option 4 to ON the display shows the current projector addressing to view the dimme...

Page 13: ...in DMX male and plug must be carried out as per following description pin 1 function GND SHIELD pin 2 function SIGNAL pin 3 function SIGNAL Please make sure cables are properly connected Use shielded...

Page 14: ...ioning length is described as per picture 2 Colour scene length can be set by pushing SELECT the dsiplay will show PA 0 Push and to set the speed Pre programmed colour scenes length is described as pe...

Page 15: ...TENANCE All lanterns require regular maintenance to ensure maximum performance and light output Please follow these instructions clean lenses mirrors and dichroics regularly as even a thin layer of du...

Page 16: ...d Lamp Fuse 6x30 250V 10A Electtronic System fuse 5x20 250V 3 25A Max Working Temperature 130 C Max Ambient Temperature 40 C The European Directive 2002 96 EC on Waste Electrical and Electronic Equipm...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...LENGE Professional Lighting Manufacturer Via Bulgaria 16 46042 CASTEL GOFFREDO MN Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mai...