MOUNTING POSITION
COLORWAY can be mounted in any position.
The minimum distance from flammable objects or the wall must be 0.5m so as to make air circula-
tion easy.
FIXING THE LANTERN
Fork
A 12,5 mm Ø hole is provided in the fork to fix the lan-
tern to a clamp or a bracket.
ELECTRICAL CONNECTION
1) Cable the mains plug with a supply cable of 3x2.5mm2 (minimum suggested size).
2) Connect the ballast to the projector through the relevant cable and safety club and then the bal-
last to a mains supply of 230V - 50/60Hz.
3) Make sure the mains supply unit is correctly grounded.
The power line shall be provided with safety switch.
4) The lantern is fitted with power factor correction.
PLUGS CONNECTION
The connection of the XLR 3 poles must be as follows:
pin 1---> function GND (SHIELD)
pin 2---> function SIGNAL -
pin 3---> function
Please check that the cables are properly connected.
Use shielded cable.