![Grindmaster Cecilware 1004-001 Operator'S Manual Download Page 7](http://html1.mh-extra.com/html/grindmaster-cecilware/1004-001/1004-001_operators-manual_2265598007.webp)
Coffee Brewers
Grindmaster
®
7
Altitude
Approximate Boiling Point
Recommended Max. Temperature
(ft)
(m)
°F
°C
°F
°C
0
0
212
100
205
96.1
500
152
211.1
99.5
204
95.6
1000
305
210.2
99.0
203
95.0
1500
457
209.3
98.5
202
94.4
2000
610
208.4
98.0
201
93.9
2500
762
207.5
97.5
200
93.3
3000
914
206.6
97.0
199
92.8
3500
1067
205.7
96.5
199
92.8
4000
1219
204.8
96.0
198
92.2
4500
1372
203.9
95.5
197
91.7
5000
1524
203
95.0
196
91.1
5500
1676
202
94.4
195
90.6
6000
1829
201.1
93.9
194
90.0
6500
1981
200.2
93.4
193
89.4
7000
2134
199.3
92.9
192
88.9
7500
2286
198.3
92.4
191
88.3
Adjustments (continued)
Control Features
Pre-infusion:
Controls the initial coffee grounds wetting and the first dwell time after the initial wetting. Pulse
brews are the series of pulses after the Pre-infusion process.
Brew Countdown Timer:
After the start of a brew the LCD display will countdown the remaining time left in
the brew process. The countdown will include all OFF periods programmed in the Pre-infusion and the pulses.
Energy Savings Mode:
If enabled, when the brewer is idle for a selectable time of 1-12 hours, this feature will
allow the water tank to lower its holding temperature to 60°C (140°F). The display will scroll through background
images while in this mode. To exit energy savings mode, press the display and the unit will start reheating to
brewing temperature.
Summary of Contents for 1004-001
Page 54: ...54 Grindmaster Coffee Brewers ...
Page 55: ...Coffee Brewers Grindmaster 55 ...